[Veritas-bu] master server crash due to disk problem how rebuilt it to restore the data

2006-12-22 Thread Sanjay . Chahar
Hi I have veritas netbackup 6.0 with solaris 8 on master server having two media server on solaris 8. These media server are connected to HP tape library with 8 drive, master media server are connected gigabit interface that is a separate network. Last night my master server is crash due

[Veritas-bu] bpschedreq -read_stunits and -read_stu_config

2006-12-22 Thread Bob Stump
NetBackup 5 and earlier what is the difference between bpschedreq commands bpschedreq -read_stunits bpschedreq -read_stu_config # man bpschedreq No manual entry for bpschedreq. ___ Veritas-bu maillist - Veritas-bu@mailman.eng.auburn.edu

Re: [Veritas-bu] 155 errors and NDMP backups

2006-12-22 Thread Martin, Jonathan \(Contractor\)
If I'm not mistaken 155 means catalog disk full, and has nothing to do with the client. Check the volume your catalog is on for disk space. -Jonathan -Original Message- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of Shane Liebling Sent: Thursday, December 21, 2006 5:33

Re: [Veritas-bu] Backup of Large Windows Volume

2006-12-22 Thread Clem Kruger
Good day, You should look at the HBA on the client and also on the data switch. The other area to look at is how the fabric has been set up. All of these will affect the through-put. One last thing to look at is to ensure that the outgoing anti-virus is turned off during the backup as the

Re: [Veritas-bu] master server crash due to disk problem how

2006-12-22 Thread bob944
I have veritas netbackup 6.0 with solaris 8 on master server having two media server on solaris 8. These media server are connected to HP tape library with 8 drive, master media server are connected gigabit interface that is a separate network. Last night my master server is crash due

Re: [Veritas-bu] DB backup tapes and DR

2006-12-22 Thread bob944
Ok I have a DR question for everyone. I have 3 sites. All 3 of them have master servers. All sites do tape vaulting and send their tapes to the main site for DR storage of a week and then are sent back. However, the db backup tapes for netbackup do not get vaulted out. I tried this once and

[Veritas-bu] Gary J Schings/GIS/CSC is on vacation

2006-12-22 Thread Gary J Schings
I will be out of the office starting 12/22/2006 and will not return until 12/27/2006. If you need immediate assistance, please contact Cheryl Barker, 203-228-2852 ___ Veritas-bu maillist - Veritas-bu@mailman.eng.auburn.edu