Most newer Autoloaders usually can be configured in AUTO/SEQUENTIAL or
RANDOM Mode - i.e. If you want the autoloader to manage library
operations (which tape to put it etc...) then you would use AUTO but
since you are using Netbackup you are probably better off switching the
Autoloader into
Hi We've got 2 media servers ( 1 windows 1 aix) that ar ecurrently
being used by an AIX master.( all NBU 6.5.2) We need to migrate these
servers to a new master - a windows 2003 x64 cluster ( license costs ) -
whats the best way to do it? We don't neccesarily need to migrate the
catalog
Cheers
Hi, I require a copy of the bpstart_notify and bpend_notify scripts for HP-UX
11i. These scripts must be copied from the master server and my master server
is windows so the scripts are .bat files
I do not have the option to install the HP-UX master server software on a
server just for the
I'm setting up MS-SQL 2005 backups with the SQL Agent and I need some
more information on clearing the transaction logs. In the past we've
used the built in wizard in SQL to configure backups to disk, then run
clean up and maintenance. We'll be replacing the backup piece with Full
and
Is there any one using IBM TS 3500 Tape Library Control Path Fail Over using
under netbackup?
IBM says to use this feature we need to use IBMtape driver.
Symantec says we need to use only ovpass/sg driver for the robots.
If we don't use Control Path Fail Over feature if a drive which has
I have a 3576, I had to install the ATAPE file set on my AIX box before
I could see the ovpass in my lsdev.
-Original Message-
From: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED] On Behalf Of rvadde
Sent: Thursday, October 23, 2008 3:19 PM
To: VERITAS-BU@mailman.eng.auburn.edu
Subject:
Thanks. In tpconfig do you use /dev/smc as the robotic path or /dev/ovpass?
According to IBM if we use /dev/ovpass robotic path will not fail over.
+--
|This was sent by [EMAIL PROTECTED] via Backup Central.
|Forward SPAM to
/dev/ovpass
-Original Message-
From: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED] On Behalf Of rvadde
Sent: Thursday, October 23, 2008 3:35 PM
To: VERITAS-BU@mailman.eng.auburn.edu
Subject: [Veritas-bu] IBM TS 3500 Tape Library Control Path Fail Over
Thanks. In tpconfig do you use
All,
Running NBU 6.5.1 on Windows 2003
I've recently been asked to backup the following OSs. Does anyone
currently back them up to 6.5.1? Are there any issues? The oldest UNIX
I currently backup is Solaris 5.7 with a 5.x client.
Not On Compatibility List:
SunOS 5.6
HP-UX B.10.20
On
There's nothing special about them - just regular shell scripts, not
different from unix to unix at all. You can start, pretty easily, from
scratch on them.
HTH - M
-Original Message-
From: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED] On Behalf Of mark
wragge
Sent: Thursday, October 23,
Ah - found them in goodies...
-Original Message-
From: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED] On Behalf Of mark
wragge
Sent: Thursday, October 23, 2008 11:41 AM
To: veritas-bu@mailman.eng.auburn.edu
Subject: [Veritas-bu] i require bpstart_notify script for HP-UX 11i
Hi, I require
Dear Sirs,
I need ur kind assistance..I have a few volume pools in my netbackup server.
Each volume pools has a few medias ( tapes ) assigned to it. Unfortunately,all
the media ( tapes ) assigned to one of the volume pools are expired and cannot
be used back for backup. So I deassign the tapes
12 matches