Hi,
Taking a shot in the dark here, for the tcp issues, try adding:
net.ipv4.tcp_tw_reuse = 1
net.ipv4.tcp_tw_recycle = 1
To your /etc/sysctl.conf, reboot.
For vnetd, check your /etc/xinetd.d/vnetd*
Also check the logs that xinetd is not throttling connections if too many
servers are trying to
Hi Forum,
I need to download 6.5.5 version for upgradation.
Also clients.
Thanks in Advance
+--
|This was sent by qureshiu...@rediffmail.com via Backup Central.
|Forward SPAM to ab...@backupcentral.com.
Hi,
Contact your support rep for the 6.5 software.
For the 6.5.x. upgrades, you can get them here:
ftp://ftp.nbu.support.veritas.com/pub/support/products/NetBackup_Enterprise_Server/
Justin.
On Wed, 20 Jan 2010, NBU wrote:
Hi Forum,
I need to download 6.5.5 version for upgradation.
Also
I'm about ready to perform a DR test
I need clarification on a few items
Master is HP-UX 11.11 @ 6.5.4
::--- DR master has a different name then the current production
system...
Would a complete restore from the production work OK after I change the DR
systems name
to
On Wed, 20 Jan 2010, Joseph Despres wrote:
I'm about ready to perform a DR test
I need clarification on a few items
Master is HP-UX 11.11 @ 6.5.4
::--- DR master has a different name then the current production
system...
Would a complete restore from the
I have been running 6.5.3.1 and doing the restore without import just
fine. I just rdist the db/images dir to a different location on my dr
master.
From: veritas-bu-boun...@mailman.eng.auburn.edu
[mailto:veritas-bu-boun...@mailman.eng.auburn.edu] On Behalf Of Joseph
Despres
Sent: Wednesday,
I have been going over the release docs on 655 and can't quite determine if
this version supports granular restore of a linux vmdk, ie, a vmdk that is a
redhat server. I this can be done with a windows vmdk without using a client
license, but rather doing a 2 stage restore. The question is, can
Justin,
Thanks for the reply. For whatever reason things seem to have magically
started working again. All I did was shutdown Veritas (again), turned up
the verbosity in bp.conf, and restarted it. When it first started I still
didn't have bpdbm, bpjobd, etc, running. The vnetd log had a lot
From here you can download all binary even client
http://seer.entsupport.symantec.com/docs/337041.htm
+--
|This was sent by apatoli...@gmail.com via Backup Central.
|Forward SPAM to ab...@backupcentral.com.
Hi Forum,
My env is Master/Media - 6.5.3 (Solaris 10)
Client - 6.5.3 (Win 2008 Ent 64bit.)
Job is failing with error 11. It is not connecting.
I am able to ping smootly from Master --Client, Client---Master.
telnet from Master on 13782 port is also successful.
Any suggestions pls.
10 matches
Mail list logo