Hi,
I think you can try the procedure here...
http://linuxplatform.blogspot.com/2010/03/netbackup-655-on-linux-redhat.html
Regards,..
+--
|This was sent by wong...@gmail.com via Backup Central.
|Forward SPAM to ab...@backupcentr
Hello Thomas.Schulz
I've done instalation of NBU 6.5.4 on SC3.2 last week.
So, I can tell, that NBU works fine on SC3.2 and there are no problems during
new installation. If you plan to upgrade NBU Server to NBU HA Server You should
contact Symantec support. ;(
Grzegorz Wodzinski
--
Senior
This is for an alternate client restore to a client that I cannot get the nbu
ports opened for. I've been told that if I can restore the rman files as plain
files, they can then be moved to an appropriate server where the dba's will be
able to restore the db from them. Does this sound correct
Learn something new every day!
From: veritas-bu-boun...@mailman.eng.auburn.edu
[mailto:veritas-bu-boun...@mailman.eng.auburn.edu] On Behalf Of Holowinski,
Scott
Sent: Tuesday, March 16, 2010 1:00 PM
To: veritas-bu@mailman.eng.auburn.edu
Subject: Re: [Veritas-bu] Need to change Media Type from
I would start with the easy stuff to look at. It almost sounds like your Data
Domain VTL tape size is larger than your MSL6060 physical LTO tape. I would
check that and compare sizes.
From: veritas-bu-boun...@mailman.eng.auburn.edu
[mailto:veritas-bu-boun...@mailman.eng.auburn.edu] On Be
I have 2 Keygroups, one for catalog backups, the other for all other backups.
Some have shown some compression degradation with the hardware compression
if hardware encryption is used which is surprising. Tapes are easily mixed
up. Unless you are absolutely certain that only your ENCR pool tapes l
Our environment, NBU 6.5.4 running on HP-UX 11-31 with a Data Domain VTL
and MSL6060 tape library. I'm trying to duplicate from a DataDomain
vtl to an lto tape. I have been duplicating things off to tape for a
while and needed to do it again but am now having issues. It has worked
in the past b
vmchange will let you change the media type, the volume group and even the
barcode on active tapes. There are more options, but those are the only ones I
have actually done.
From: judy_hinchcli...@administaff.com [mailto:judy_hinchcli...@administaff.com]
Sent: Tuesday, March 16, 2010 8:04 AM
vmchange -m -new_mt hcart2
If the media has already been loaded you will need to change the volume group
too
vmchange -m -new_v 001_1_TLD (though you will need to check what
the volume ID is on another tape to make sure, I am guessing)
Or you could move it to stand alone and re-inv
Hello,
I am working on setting up KMS. I am interested in what others are
doing for encryption with KMS. Do you encrypt all you tapes or only the
tapes going offsite?
Thanks
Dwayne Adams
___
Veritas-bu maillist - Veritas-bu@mailman.eng.au
On Fri, Mar 12, 2010 at 9:19 PM, awiggins wrote:
>
> Is there any way to restore RMAN files as standard files using bprestore?
> I've been told you can but I get the error below when I try:
>
>
What is it you are actually trying to accomplish?
Jared Still
Certifiable Oracle DBA and Part Time Pe
You cannot make any change to a tape if it has valid images on it.
So if you do not want to expire the tapes, change one of your drives to the
same media type as the tapes you want to restore from.
From: veritas-bu-boun...@mailman.eng.auburn.edu
[mailto:veritas-bu-boun...@mailman.eng.aubu
I'm getting very frustrated about having to re-invent the wheel to
reproduce the functionality of Storage Lifecycle Policies for my
Synthetic Full backups.
For those not aware, Synthetic backup images for some dumb reason that
hasn't been explained to me cannot be managed by an SLP and you will ge
Our environment, NBU 6.5.4 running on HP-UX 11-31 with a Data Domain VTL
and MSL6060 tape library. I need to change the Media Type on a few
tapes that are currently HCART to HCART2 but am having trouble. We have
changed tape libraries since these tapes were created, the tape library
is now HCART2
14 matches