It could be any number of things that is causing the reboot as others have
stated from memory, internal drives, network cards, HBAs, down to even the
components of the motherboard or even the main board its self.
If the reboot only happens when NetBackup is initiated then perhaps it could be
If NetBackup is unable to write to the log files it will stall and not
run. Check the logs directory and also the logs in the db directory
sometimes they can get to be many GB in size. Either remove them or move
them to another spot to free up space. At least that is what occurred to
us when we
Is it common that Disk storage systems are able to use DC 48 volt power,
or is this rare? When I ask about DC I either get a flat out no or it
is like I've knocked the sales people off guard and they have to get
back to me on that.
Has anybody else run into this?
Dustin D'Amour
Wireless
Upgrading is non destructive (unless previous version was uninstalled
first) so the license key should still be in the master server config.
If it is UNIX based it would be located at:
/usr/openv/netbackup/bin/admincmd # ./get_license_key
Option F will list the Active License Keys and
I think the technical terms for this is Cold Backup which requires the
database to be stopped before backup. Hot Backup is when there is an
agent or some other software that doesn't shut down the database, and
instead takes a snapshot in a point of time while data can be written
still after
When we had a client with Oracle we used bpstart_notify and bpend_notify to
bring down the Oracle service and then bring it back up. It works like a charm.
Dustin D'Amour
Wireless Switch Technician
Plateau Wireless
575.389.4189 - office
575.309.6372 - cell
dust...@plateautel.com
I could never get LU to install and actually work. I ended up just
settling on updating each of the clients through the install client
script. It may be a pain the first time, but I set up authentication key
access to speed up direct access from master-to-client.
Now it just takes a few
The big list of everything you can download for 6.5.3
From: Dustin Damour dust...@plateautel.com
To: veritas-bu@mailman.eng.auburn.edu
Sent: Friday, January 30, 2009 1:34:20 PM
Subject: [Veritas-bu] Filename for Java Admin Console option Windows
I’m wanting
without help (even
a reboot where poss!)
HTH
S.
From: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED] On Behalf Of Dustin
Damour
Sent: Tuesday, February 19, 2008 4:32 PM
To: veritas-bu@mailman.eng.auburn.edu
Subject: [Veritas-bu] bpbrm utilizing 99.9% CPU
I've
I've noticed in the past that bpbrm is utilizing 99.9% of the CPU and
hasn't let down. Also it says it has used 15436:40 CPU Time which seems
like the process has gone rogue. Has anyone else had this happen or is
this normal, and how would I fix it?
NetBackup 6.5
Dustin D'Amour
Wireless
To: Dustin Damour
Cc: veritas-bu@mailman.eng.auburn.edu
Subject: Re: [Veritas-bu] bpbrm utilizing 99.9% CPU
Dustin,
Do you have any stuck jobs? I've seen this happen in the past where a
client also has problems. Backups generate incomplete errors and the
master/media server responsible for writing
I would say no as Wikipedia is like an encyclopedia and is a good spot
to start but it isn't peer reviewed published articles so in research it
would not be considered a valid source.
Dustin D'Amour
Wireless Switching
Plateau Wireless
-Original Message-
From: [EMAIL PROTECTED]
: Humenik, Joe - BLS [mailto:[EMAIL PROTECTED]
Sent: Tuesday, October 16, 2007 12:00 PM
To: Dustin Damour; veritas-bu@mailman.eng.auburn.edu
Subject: RE: [Veritas-bu] reference to path doesn't exist
Is it in an include list?
Joe Humenik
[EMAIL PROTECTED]
Because e-mail can be altered
Yes, all policies are clear of the /csg path.
Dustin D'Amour
Wireless Switching
From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED]
Sent: Wednesday, October 17, 2007 2:26 PM
To: Dustin Damour
Cc: veritas-bu@mailman.eng.auburn.edu;
[EMAIL PROTECTED]
Subject: Re: [Veritas-bu] reference
Thanks, I'll try that and see if it resolves the errors.
Dustin D'Amour
Wireless Switching
Plateau Wireless
From: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED]
Sent: Wednesday, October 17, 2007 2:41 PM
To: Dustin Damour; veritas-bu@mailman.eng.auburn.edu
Subject: RE: [Veritas-bu
-
From: Justin Piszcz [mailto:[EMAIL PROTECTED]
Sent: Wednesday, October 17, 2007 2:52 PM
To: Dustin Damour
Cc: veritas-bu@mailman.eng.auburn.edu
Subject: Re: [Veritas-bu] reference to path doesn't exist
And the include or exclude files on the client are blank?
On Wed, 17 Oct 2007, Dustin
Justin,
I find it hard to get any type of information out of Symantec on
unsupported features.
Dustin D'Amour
Wireless Switching
Plateau Wireless
-Original Message-
From: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED] On Behalf Of
[EMAIL PROTECTED]
Sent: Wednesday, October 17, 2007 5:25 PM
This is for NetBackup 6.5 Linux
Every day I'm getting the following errors:
10/16/2007 07:02:56 ptclvsbkp01.nmplateaugsm.com -
sts_get_lsu_prop_byname on LSU /csg failed: 2060013 no more entries
10/16/2007 07:02:56 ptclvsbkp01.nmplateaugsm.com - Invalid storage
device: /csg
18 matches