[Veritas-bu] Status 84 - plugin error

2011-10-27 Thread rsavage
Yea, Data Domain want us to upgrade to 5.0.2.3 also but they cannot pinpoint any reason for the code 84. Right now we are staying at 5.0.1.7 as the media write errors are very very few now. I even asked datadomain to give the solution id that specifically addresses the media write error in the

Re: [Veritas-bu] Status 84 - plugin error

2011-10-21 Thread Jack . Forester
:[Veritas-bu] Status 84 - plugin error Sent by:veritas-bu-boun...@mailman.eng.auburn.edu We had the same problem, media write errors. Seems to happen with long running jobs most of the time. We ugpraded the Data domain code and OST code which increased the timeouts to 3hrs from data domain

[Veritas-bu] Status 84 - plugin error

2011-10-21 Thread X_S
Hi Jack, i'll second rsavage. we had to upgrade to 5.0.1.7 and use the symantec patch for 2008 servers as well which definitely helped. We worked for a few weeks before we got a hold of the right person at DD to figure this out. DD support has been great but they need to do a better job

[Veritas-bu] Status 84 - plugin error

2011-10-20 Thread rsavage
We had the same problem, media write errors. Seems to happen with long running jobs most of the time. We ugpraded the Data domain code and OST code which increased the timeouts to 3hrs from data domain. We also noticed are long running jobs in which most of the 84 errors were coming from were

[Veritas-bu] Status 84 - plugin error

2011-10-19 Thread Jack . Forester
We've been having jobs fail with a status 84 seemingly at random. These jobs are being written to a DataDomain 890 configured as an OST target for the backups. Both of the media servers in the environment (one AIX and one Windows) are seeing these failures. Since NetBackup is reporting a

Re: [Veritas-bu] Status 84 - plugin error

2011-10-19 Thread David Stanaway
We have seem similar issues when we exceed the max streams on the DD system. Synth jobs take up 3 streams, duplication jobs take up 2 streams, so you need to be careful with the max jobs on the storage unit. If this is happening you will see messages logged in your daily autosupports (No