[Veritas-bu] bpcd 13782 - drops connection from master server

2011-09-20 Thread brettkan
It may be an issue from some work network did in regards to reverse lookup. Troubleshooting that with sys admins now. I'll post results once I have them. thanks. +-- |This was sent by brett.t.kand...@fisglobal.com via Backup

[Veritas-bu] bpcd 13782 - drops connection from master server

2011-09-16 Thread brettkan
The issue - when master server initiates a session to client on port 13782, it drops immediately. Thus, bkps are not running. We are migrating clients off an old NetBackup server to this new server. Tests done: 1-client can telnet to master server on ports 13782 (and maintains connection)

Re: [Veritas-bu] bpcd 13782 - drops connection from master server

2011-09-16 Thread Marianne Van Den Berg
@MAILMAN.ENG.AUBURN.EDU Subject: [Veritas-bu] bpcd 13782 - drops connection from master server The issue - when master server initiates a session to client on port 13782, it drops immediately. Thus, bkps are not running. We are migrating clients off an old NetBackup server to this new server. Tests done

Re: [Veritas-bu] bpcd 13782 - drops connection from master server

2011-09-16 Thread Lightner, Jeff
[mailto:veritas-bu-boun...@mailman.eng.auburn.edu] On Behalf Of Marianne Van Den Berg Sent: Friday, September 16, 2011 1:08 PM To: 'veritas-bu@mailman.eng.auburn.edu' Subject: Re: [Veritas-bu] bpcd 13782 - drops connection from master server Which NBU version? Since 6.0 server/client connection use vnetd

[Veritas-bu] bpcd 13782 - drops connection from master server

2011-09-16 Thread brettkan
Here are the answers to your questions Hi Marianne - Which NBU version? - client 7.0; master 7.1 Hi Jeff - Are you removing the old master from bp.conf on the clients and putting in the new master? Adding the new master server / leaving old master for future restores. Are you upgrading NBU

Re: [Veritas-bu] bpcd 13782 - drops connection from master server

2011-09-16 Thread Patrick
...@mailman.eng.auburn.edu [mailto:veritas-bu-boun...@mailman.eng.auburn.edu] On Behalf Of brettkan Sent: 16 September 2011 18:41 To: VERITAS-BU@MAILMAN.ENG.AUBURN.EDU Subject: [Veritas-bu] bpcd 13782 - drops connection from master server The issue - when master server initiates a session to client on port

[Veritas-bu] bpcd 13782 - drops connection from master server

2011-09-16 Thread brettkan
neither bpcd or vnetd are logging anything when I kick off the bkps. Nothing is registering there. +-- |This was sent by brett.t.kand...@fisglobal.com via Backup Central. |Forward SPAM to ab...@backupcentral.com.

Re: [Veritas-bu] bpcd 13782 - drops connection from master server

2011-09-16 Thread Nic Solomons
- Reply message - From: Patrick netbac...@whelan-consulting.co.uk Date: Fri, Sep 16, 2011 18:46 Subject: [Veritas-bu] bpcd 13782 - drops connection from master server To: VERITAS-BU@MAILMAN.ENG.AUBURN.EDU VERITAS-BU@MAILMAN.ENG.AUBURN.EDU What do the bpcd vnetd logs on the clients show

Re: [Veritas-bu] bpcd 13782 - drops connection from master server

2011-09-16 Thread Daniel Otto
: veritas-bu-boun...@mailman.eng.auburn.edu [mailto:veritas-bu-boun...@mailman.eng.auburn.edu] On Behalf Of brettkan Sent: Friday, September 16, 2011 1:06 PM To: VERITAS-BU@MAILMAN.ENG.AUBURN.EDU Subject: [Veritas-bu] bpcd 13782 - drops connection from master server neither bpcd or vnetd

Re: [Veritas-bu] bpcd 13782 - drops connection from master server

2011-09-16 Thread Mikhail Nikitin
Try the 1556 port. NBU client tries to use 1556 by default since 7.0.1 IIRC Also bpcd could drop connection if it cannot resolve the new master's hostname (forward or reverse). This can be catched with bptestbpcd. WBR, Mikhail On Fri, Sep 16, 2011 at 9:33 PM, brettkan

[Veritas-bu] bpcd 13782 - drops connection from master server

2011-09-16 Thread brettkan
Did generate a log when I typed : /usr/openv/netbackup/logs/bpcd /usr/openv/netbackup/logs/bpcd [352]root: cat log.091611 14:41:24.082 [15390] 2 setup_debug_log: switched debug log file for bpcd 14:41:24.083 [15390] 2 bpcd main: VERBOSE = 0 14:41:24.083 [15390] 2 logparams: bpcd 14:41:24.089

Re: [Veritas-bu] bpcd 13782 - drops connection from master server

2011-09-16 Thread Marianne Van Den Berg
] On Behalf Of brettkan Sent: 16 September 2011 07:34 PM To: VERITAS-BU@MAILMAN.ENG.AUBURN.EDU Subject: [Veritas-bu] bpcd 13782 - drops connection from master server Here are the answers to your questions Hi Marianne - Which NBU version? - client 7.0; master 7.1 Hi Jeff - Are you removing the old

Re: [Veritas-bu] bpcd 13782 - drops connection from master server

2011-09-16 Thread Daniel Otto
, 2011 2:43 PM To: VERITAS-BU@MAILMAN.ENG.AUBURN.EDU Subject: [Veritas-bu] bpcd 13782 - drops connection from master server Did generate a log when I typed : /usr/openv/netbackup/logs/bpcd /usr/openv/netbackup/logs/bpcd [352]root: cat log.091611 14:41:24.082 [15390] 2 setup_debug_log: switched

Re: [Veritas-bu] bpcd 13782 - drops connection from master server

2011-09-16 Thread Reynolds, Susan K.
, September 16, 2011 9:41 AM To: VERITAS-BU@MAILMAN.ENG.AUBURN.EDU Subject: [Veritas-bu] bpcd 13782 - drops connection from master server The issue - when master server initiates a session to client on port 13782, it drops immediately. Thus, bkps are not running. We are migrating clients off