[Veritas-bu] Inventory Cleaning tape failed

2006-12-08 Thread Yoseph Leleputra
Dear NBU Expert This week i got a confused with inventory robot for my cleaning cartridge When i add 2 cleaning cartridge to library and robotic can read their CLN405 and CLN406 But when i run inventory robot , netbackup can not find their label so netbackup give them a logical label A0

Re: [Veritas-bu] help please

2006-12-08 Thread Bob Stump
What I like about CDC/OpenVision/VERITAS/symantec Backup Plus/AXXion-NetBackup/NetBackup whatever product Is that there are many different ways to configure and run it. All of them have benefits and drawbacks. It keeps the product interesting. I'm OK, you're OK, our backups are OK ...wow

[Veritas-bu] Question posed to ACSLS/STK8500 users.

2006-12-08 Thread Justin Piszcz
All, My group is setting up two Sun/StorageTek SL8500s. Sun did the install of ACSLS, there were no problems on their side. Each SL8500 is in its own environment. On each SL8500, we have 8 media servers, connected to four drives each, giving us a total of 32 drives. For testing, I did the

Re: [Veritas-bu] Backups vs archives

2006-12-08 Thread Curtis Preston
I was asked for a URL of this article. It's available at storage magazine: http://tinyurl.com/ygjlcj (Original URL is http://searchstorage.techtarget.com/magItem/0,291266,sid35_gci1216875,00 .html , but that is probably truncated.) --- W. Curtis Preston, Author of O'Reilly's Backup Recovery

Re: [Veritas-bu] Question posed to ACSLS/STK8500 users.

2006-12-08 Thread Hampus Lind
Hi, Do you have umount delay set? It takes some time for tapes to travel within the SL8500, especially if they need to take the elevator. Do you have the latest microcode/firmware on the drives and the library? Hampus Lind Rikspolisstyrelsen National Police Board Tel dir: +46 (0)8 - 401 99 43

Re: [Veritas-bu] Question posed to ACSLS/STK8500 users.

2006-12-08 Thread Justin Piszcz
Yeah, its either 120 or 180 seconds I believe, what is yours set to? Justin. On Fri, 8 Dec 2006, Hampus Lind wrote: Hi, Do you have umount delay set? It takes some time for tapes to travel within the SL8500, especially if they need to take the elevator. Do you have the latest

Re: [Veritas-bu] Lost Mediadb

2006-12-08 Thread Juan Pablo Almeida
I have recovered de old mediaDB yesterday, now I have 2 options, merge the mediadb or recreate the media entry. (How can I merge this databases?) The doc http://seer.support.veritas.com/docs/262590.htm, creates the media entry by rentetion is lost, How can I set the retention in this tapes?

Re: [Veritas-bu] Question posed to ACSLS/STK8500 users.

2006-12-08 Thread Fielden, Joshua
Yeah, its either 120 or 180 seconds I believe, what is yours set to? 10 mins is what we set to, and never have a problem with the same library. On Fri, 8 Dec 2006, Hampus Lind wrote: Hi, Do you have umount delay set? It takes some time for tapes to travel within the SL8500, especially if

Re: [Veritas-bu] Question posed to ACSLS/STK8500 users.

2006-12-08 Thread Mike Dunn (veritas-bu)
Justin, Are you absolutely certain that you have your drive mapping done properly? The fact that the job fails 30 minutes after the initial mount attempt makes it sound like you are failing with a media mount time out. The most common cause (especially with ACS environments) is a simple

Re: [Veritas-bu] Question posed to ACSLS/STK8500 users.

2006-12-08 Thread Hampus Lind
We have it set to 200.. But sometimes we have issues with netbackup releasing tapes after backups. Sometimes the tape stays in the drive for 30-40 minutes, even if we have jobs in queue. We have logged cases to Symantec about this and also to STK/SUN. But no one can tells us what`s wrong. We had

Re: [Veritas-bu] New Media Server

2006-12-08 Thread mkiles
When tapes are added, NBU puts them in different Volume Groups and there is always a different volume group for a different library. You just need to configure one scratch pool and make sure you put enogh tapes in it from each robot. MK --- Paul Keating [EMAIL PROTECTED] wrote: I've never had

Re: [Veritas-bu] Question posed to ACSLS/STK8500 users.

2006-12-08 Thread Justin Piszcz
It is 100% correct. Yep. I ran about 5 test backups to each drive in the robot. No problems. It is only when there is a burst of jobs. Justin. On Fri, 8 Dec 2006, Mike Dunn (veritas-bu) wrote: Justin, Are you absolutely certain that you have your drive mapping done properly? The fact

[Veritas-bu] New robot

2006-12-08 Thread Deiter Scott
Next week we begin the installation of the new fibre attached robot. This will be zoned along with our clariion san. This san is connected to our two largest solaris 8 and 9 servers. What book do I begin with to enable netbackup 5.1 mp4 to use this new hardware. In our current setup all the

Re: [Veritas-bu] Question posed to ACSLS/STK8500 users.

2006-12-08 Thread Justin Piszcz
Yes everything matches perfectly. Remember, if I run the backups slowly, one at a time, I can see each of the 4 drives being used per each media server. When I run a burst of jobs though, 29-30 of them work (1 tape per each drive) and a RANDOM 2-3 drives do not work (it differs each time I do

Re: [Veritas-bu] Question posed to ACSLS/STK8500 users.

2006-12-08 Thread Hall, Christian N.
Justin, Do the ACSLS,LSM,PANEL,DRIVE NUMBER for ACSLS match serial number results from the tpautconf -t on the master server /dev/rmt/*cbn? Can you please display the output? Did you perform this test from your master server, or did you perform this test from each host that are media servers?

Re: [Veritas-bu] Question posed to ACSLS/STK8500 users.

2006-12-08 Thread Mike Dunn (veritas-bu)
Hmmm, do your media server's have multiple NIC, and are you using IP multipathing software? (like in.mpathd under Solaris) If so, then make sure that you have set the ACS_SSI_HOSTNAME appropriately in your vm.conf file. The acs daemon inserts the value (or inferred value) of ACS_SSI_HOSTNAME

Re: [Veritas-bu] Question posed to ACSLS/STK8500 users.

2006-12-08 Thread Justin Piszcz
I believe I am, I will try this next week, thanks! Justin. On Fri, 8 Dec 2006, Mike Dunn (veritas-bu) wrote: Are you using UDP for communication with your acs server? (UDP is default). If is, try switching to TCP. Cheers Mike On 2:16:50 pm 2006-12-08 Justin Piszcz [EMAIL

Re: [Veritas-bu] Question posed to ACSLS/STK8500 users.

2006-12-08 Thread Justin Piszcz
Nope, only 1 NIC. And even so yeah I do specify that in the vm.conf just incase. Justin. On Fri, 8 Dec 2006, Mike Dunn (veritas-bu) wrote: Hmmm, do your media server's have multiple NIC, and are you using IP multipathing software? (like in.mpathd under Solaris) If so, then make sure

Re: [Veritas-bu] Question posed to ACSLS/STK8500 users.

2006-12-08 Thread Mike Dunn (veritas-bu)