[Veritas-bu] Backup of CFO luns fails on FAS 3070 filer using NBU

2011-03-14 Thread ajaydrmgr
Hi, I have two FAS 3070 filer with infiband connectivity between two filer. I have created volume vol1 on filer 1 and copied some data to that volume. I have enabled CF on both the filer. And I ran CF failover command from filer 2. Filer 1 goes for gracefull shutdown. I am able to see the

Re: [Veritas-bu] Backup of CFO luns fails on FAS 3070 filer using NBU

2011-03-14 Thread Jeff Cleverley
Ajay, It looks like there is something wrong in your failover settings. You might check the cf.hw_assist.partner.address option and make sure it has the partner IP address. If you can't ping the filer that was taken over something isn't correct. You can also walk through the setup command. It

[Veritas-bu] Boot server for BMR

2011-03-14 Thread Patrick
Hi All, Does anyone know if a master server can also be a boot server? Is this supported? Or is it not possible? Regards, Patrick Whelan VERITAS Certified NetBackup Support Engineer for UNIX. VERITAS Certified NetBackup Support Engineer for Windows.

Re: [Veritas-bu] Boot server for BMR

2011-03-14 Thread Jon Bousselot
I've setup a Solaris SPARC NBU master as a boot server with version 6.x. I've also used a media server in the same role.It worked and I cannot remember if it was supported at the time, but it did work as advertised.-JonFrom: Patrick netbac...@whelan-consulting.co.ukTo: