Todd,
The routine looks like this on the Output Console:
HP3458A
24.4
0
1
The 0 pops up after several seconds and the 1 after even more seconds
later. No other output after the 1.
The temperature reading is OK but no voltage readings.
Thanks for the assistance but I likely have a
Randy,
Check that your firmware version on the Prologix is up to date. The latest
USB version is 6.107. You can see it in the Prologix GPIB Configurator
utility that can be downloaded from a link on their website.
http://prologix.biz/resources.html
I have uploaded a pic of my settings shown in