My 732b is fine but its transformer bit the dust before I got it.
Actually, that's probably WHY I got it on fleabay.. its previous
owner changed the battery and still couldn't get it to charge!
So it went on fleabay as 'parts/not working'..
for a price I could afford!
The primary is cooked.
I'm guessing that the 4214 10K standard has a resistance curve
that peaks around 73F??? I've searched for old pix of data and can't find
any. The 4214 I got this week had no old, original data with it in its box.
Over the past few years there have been some resistance standards
sold on fleabay
Topics:
1. Re: AC Voltage Measurement Standards (Todd Micallef)
2. Fluke 5200A repair. (Kgoodhew)
3. Need info on LN 4214 temp vs resistance plot.. (new)
4. Re: Need info on LN 4214 temp vs resistance plot..
(Mitch Van Ochten
I've been using an old HP GPIB card in a pci slot in my 7 year old PC.
It's running win7 with the latest version of Agilent Connection Expert
and I've had the 3458 and three 3457s all hooked up at once with no
problems. I don't have any lab programs, just hand-enter commands
and then
I find no 'search' function on here... How do you get to
the GPIBKIT ?
Willy
On 2/20/2015 12:00 PM, volt-nuts-requ...@febo.com wrote:
Send volt-nuts mailing list submissions to
volt-nuts@febo.com
To subscribe or unsubscribe via the World Wide Web, visit
I'm thinking of doing non-commercial 'calibrations' for
folks like us volt-nuts.
Since I have three 3458s, three 732As, a 732b, a 4214,
an sr104, a 4210, all NIST cal'ed and I could do front-panel
adjustments for the 3457.
Would anyone here like to do that? I would start by
replacing the cal
Fluke equipment
Message-ID:
<CAM+CiWO19c3WAV=f5vfalnyxcz4elywvwcfuhku2mqselba...@mail.gmail.com>
Content-Type: text/plain; charset=UTF-8
Hello to everyone, I am new to this group and my english is bad, so I will
made this post quick.
In my little home workshop I have a functional bu
My favorite DMM has gone far beyond my 1990 model... The HFC, for
example. Questions about the upgrades
1) Is the HFC option just a high quality reference, or are there other
differences in the machine to go along with the reference?
2) Is there a Hi voltage AC option? I use probes now,
I have a 4708 on fleabay now which needs a front panel.
Or at least a display, since the left side display (frequency) is broken.
If I could get it working, I could use it for my 3457 work.
Willy
___
volt-nuts mailing list -- volt-nuts@febo.com
Ever wonder why they haveĀ FOUR 732b units in a 734?
(smile) You need at least 3 of anything unknown. 4 is better.
On 8/31/2017 12:00 PM, volt-nuts-requ...@febo.com wrote:
Send volt-nuts mailing list submissions to
volt-nuts@febo.com
To subscribe or unsubscribe via the World Wide
10 matches