On 2013-05-26 23:21, Jed Rothwell wrote:

A Swedish correspondent sent me this link:

http://www.energikatalysatorn.se/forum/viewtopic.php?f=2t=560sid=5450c28dab532569dee72f88a43a56f0start=330




Thanks for linking these observations. I think they are very important. 
I wonder why they haven't been included in the report, along with more 
information about observations and sanity checks performed by the 
testers and pictures of good quality of the equipment used. I still 
can't believe that there's not a single photo of the E-Cat control box 
or even a schematic diagram of the entire testing setup.


Cheers,
S.A.



Re: [Vo]:Torbjorn Hartman describes power measurments

2013-05-26 Thread Eric Walker
On Sun, May 26, 2013 at 7:01 PM, Duncan Cumming spacedr...@cumming.infowrote:

 So unless you use a DC rated current meter (such as a shunt) you will not
 sense all of the current, and hence power, drawn from the wall socket.


I see.  Then it would seem that if there was any kind of rectification in
the controller that ended up being delivered to the heaters, even if it was
benign, this would have been missed in the E-Cat test, and that AC current
clamps were not a sufficient tool for measuring power even if there was no
concern about fraud.

Eric

(I have edited the subject to get rid of the unicode character.)