Hi Matt,
Thanks for the fast reply. Yes, I can confirm that the patch solves this issue.
Thanks again,
BR/Mechthild
From: Matthew Smith
Sent: Friday, 18 February 2022 22:43
To: Mechthild Buescher
Cc: vpp-dev@lists.fd.io
Subject: Re: [vpp-dev] VRRP issue when using VRs in different VLANs
Hi
Hi Mechthild,
It looks like you are running version 21.06 of VPP. This patch was merged
last month and may resolve the issue - https://gerrit.fd.io/r/c/vpp/+/34815.
Can you try applying that patch to your build?
Let me know if that helps.
Thanks,
-Matt
On Fri, Feb 18, 2022 at 3:06 PM
Hi all,
We are using VPP on two nodes and run VRRP on them. This works fine as long as
we use one VLAN. But if we configure VRs in different VLANs we see strange
behavior: Every 4 seconds, the backup VRRP VR shortly changes to master and
sends an advertisement message to the master and then
@lists.fd.io
Subject: Re: [vpp-dev] VRRP issue when using interface in a table
Hi Matt,
Thanks for the patch. I can confirm that the patch solves the vrrp issue and
from what we see until now, it doesn’t break other traffic handled by that
interface. So everything is fine
Fyi: We applied the patch
: Matthew Smith
Sent: Friday, 2 July 2021 23:01
To: Mechthild Buescher
Cc: Neale Ranns ; vpp-dev@lists.fd.io
Subject: Re: [vpp-dev] VRRP issue when using interface in a table
Hi Mechthild,
Here is a patch you can try -
https://gerrit.fd.io/r/c/vpp/+/32999<https://protect2.fireeye.com/v1/ur
up), the peer node changes back to state backup.
>
>
>
> It would be nice if you can tell me how to disable source pruning with
> DPDK PMD.
>
>
>
> Thank you,
>
>
>
> BR/Mechthild
>
>
>
> *From:* Matthew Smith
> *Sent:* Friday, 2 July 2021 16:06
> *T
Sent: Friday, 2 July 2021 16:06
To: Neale Ranns
Cc: Mechthild Buescher ; vpp-dev@lists.fd.io
Subject: Re: [vpp-dev] VRRP issue when using interface in a table
There could be an issue with the NIC:
vpp# show hardware-interfaces
NameIdx Link Hardware
Ext-0
Core VRRP issues I can’t help with, I no next to nothing about VRRP. I’ll
> hand over to those who do.
>
>
>
> /neale
>
>
>
>
>
> *From: *vpp-dev@lists.fd.io on behalf of Mechthild
> Buescher via lists.fd.io
> *Date: *Thursday, 1 July 2021 at 22:55
> *To: *vp
dev@lists.fd.io<mailto:vpp-dev@lists.fd.io>
mailto:vpp-dev@lists.fd.io>>
Subject: [vpp-dev] VRRP issue when using interface in a table
Hi all,
we are using VPP on two nodes where we would like to run VRRP. This works fine
if the VRRP VR interface is in fib 0 but if we but the interface into FIB t
>
mailto:vpp-dev@lists.fd.io>>
Subject: [vpp-dev] VRRP issue when using interface in a table
Hi all,
we are using VPP on two nodes where we would like to run VRRP. This works fine
if the VRRP VR interface is in fib 0 but if we but the interface into FIB table
1 instead, VRRP is not work
hild
Buescher via lists.fd.io
mailto:mechthild.buescher=ericsson@lists.fd.io>>
Date: Thursday, 24 June 2021 at 10:49
To: vpp-dev@lists.fd.io<mailto:vpp-dev@lists.fd.io>
mailto:vpp-dev@lists.fd.io>>
Subject: [vpp-dev] VRRP issue when using interface in a table
Hi all,
we
Hi Mechthild,
You’ll need to include:
https://gerrit.fd.io/r/c/vpp/+/32298
/neale
From: vpp-dev@lists.fd.io on behalf of Mechthild Buescher
via lists.fd.io
Date: Thursday, 24 June 2021 at 10:49
To: vpp-dev@lists.fd.io
Subject: [vpp-dev] VRRP issue when using interface in a table
Hi all
Hi all,
we are using VPP on two nodes where we would like to run VRRP. This works fine
if the VRRP VR interface is in fib 0 but if we but the interface into FIB table
1 instead, VRRP is not working correctly anymore. Can you please help?
Our setup:
* 2 nodes with VPP on each node and one
eply-To: *"mgsm...@netgate.com"
> *Date: *Friday, August 14, 2020 at 2:47 PM
> *To: *"Naveen Joy (najoy)"
> *Cc: *"vpp-dev@lists.fd.io"
> *Subject: *Re: [vpp-dev] VRRP issue
>
>
>
>
>
> Hi Naveen,
>
>
>
> See replies inline be
Hi Naveen,
See replies inline below...
On Fri, Aug 14, 2020 at 12:53 PM Naveen Joy (najoy) wrote:
> Thanks, Matthew. I am seeing the same behavior with the default
> advertisement interval of 1s.
>
> Tcpdump on a linux tap interface plugged into the same BD as the backup VR
> shows VRRP
Thanks, Matthew. I am seeing the same behavior with the default advertisement
interval of 1s.
Tcpdump on a linux tap interface plugged into the same BD as the backup VR
shows VRRP advertisements arriving at the configured rate of 1s (100cs),
So, there is no packet loss of advertisements or
Hi Naveen,
Generally a transition from backup to master occurs if the master down
timer expires and no advertisement has been received. So it seems like some
advertisement packets from the higher priority VR are not being received or
are not being processed before the timer expires. Since the
of "Naveen Joy via lists.fd.io"
Reply-To: "Naveen Joy (najoy)"
Date: Thursday, August 13, 2020 at 3:34 PM
To: "mgsm...@netgate.com"
Cc: "vpp-dev@lists.fd.io"
Subject: [vpp-dev] VRRP issue
Hi Matthew/All,
I am facing an issue with VRRP in VPP an
18 matches
Mail list logo