Re: [PATCH weston 09/25] libinput: do not switch output associations on disable

2018-04-05 Thread Pekka Paalanen
On Thu, 5 Apr 2018 16:10:53 +1000 Peter Hutterer wrote: > On Fri, Mar 23, 2018 at 02:00:49PM +0200, Pekka Paalanen wrote: > > From: Pekka Paalanen > > > > If an input device is associated to an output that then gets disabled, > > there

Re: [PATCH weston 09/25] libinput: do not switch output associations on disable

2018-04-05 Thread Peter Hutterer
On Fri, Mar 23, 2018 at 02:00:49PM +0200, Pekka Paalanen wrote: > From: Pekka Paalanen > > If an input device is associated to an output that then gets disabled, > there is no case where associating to a different output would be > correct. just a general note

[PATCH weston 09/25] libinput: do not switch output associations on disable

2018-03-23 Thread Pekka Paalanen
From: Pekka Paalanen If an input device is associated to an output that then gets disabled, there is no case where associating to a different output would be correct. The output association is used for absolute positioned input devices, and an input device like a