[weewx-user] Re: WeeWx and adding Ecowitt WH41 AQI sensor

2022-08-05 Thread brack...@gmail.com
Bingo, thanks Gary. Yes, forcing the WH41 to channel 1 has made it appear on Weewx stats page without any further intervention! Easy when you know how :) lcsneil On Thursday, 4 August 2022 at 21:36:08 UTC+1 gjr80 wrote: > Rather than the driver expecting a different tag I think this is more

[weewx-user] Re: WeeWx and adding Ecowitt WH41 AQI sensor

2022-08-04 Thread vince
Cool explanation of how the channel numbers affect what the station reports to the driver. Thanks On Thursday, August 4, 2022 at 1:36:08 PM UTC-7 gjr80 wrote: > Rather than the driver expecting a different tag I think this is more of a > case of WeeWX (by default when using the

[weewx-user] Re: WeeWx and adding Ecowitt WH41 AQI sensor

2022-08-04 Thread gjr80
Rather than the driver expecting a different tag I think this is more of a case of WeeWX (by default when using the view_extended schema) expecting PM2.5 data to appear in the field pm2_5. The fact you are seeing your PM2.5 data appear in the field pm2_52 and wh41_ch2_batt and wh41_ch2_sig are

[weewx-user] Re: WeeWx and adding Ecowitt WH41 AQI sensor

2022-08-04 Thread vince
Quick look at the driver says it expects a different tag than the one you're seeing. I think you might need something like: [[field_map_extensions]] pm2_5 = pm2_52 ref: https://github.com/gjr80/weewx-gw1000/wiki/Available-config-options -- You received this message because you are