Re: [weewx-user] Windchill Text Value / Graph Discrepancy

2023-01-03 Thread gjr80
Just to clarify, the linked post above dealt with an issue where the user noticed the wind chill value displayed on his Vantage2 console did not match the wind chill value displayed by WeeWX. The reason was the console displayed the value calculated by the console, but WeeWX displayed the wind

Re: [weewx-user] Windchill Text Value / Graph Discrepancy

2023-01-03 Thread Steve Schindler
My apologies. I probably could have phrased that better. You are correct that VP2s can generate windchill via hardware; however, an older unit like mine with older firmware doesn't send the windchill value in the LOOP packets. On Tuesday, January 3, 2023 at 9:39:03 AM UTC-5

Re: [weewx-user] Windchill Text Value / Graph Discrepancy

2023-01-03 Thread 'John Kline' via weewx-user
> Tom and Gary confirmed that the VP2 hardware generated values for windchill are only available in the LOOP2 packets.I’m not sure why you think that is relevant.  The question is, whether software or hardware generated, do the loop packets have windchill.  I confirmed they do contain windchill

Re: [weewx-user] Windchill Text Value / Graph Discrepancy

2023-01-03 Thread Steve Schindler
Thanks for the suggestion but I don't think that's the issue with my setup. In a previous discussion (https://groups.google.com/g/weewx-user/c/roOG0u8YPX4/m/Tc4vWnznAgAJ), Tom and Gary confirmed that the VP2 hardware generated values for windchill are only available in the LOOP2 packets.

Re: [weewx-user] Windchill Test Value / Graph Discrepancy

2022-12-31 Thread 'John Kline' via weewx-user
Tom and friends will know for sure, but I believe the low you are seeing (at 07:31) is from the archive_day_windchill table.You likely have the following in your weewx.conf    # Whether to include LOOP data in hi/low statistics    loop_hilo = TrueThis tells weewx (well, it tells it to do exactly

Re: [weewx-user] Windchill vs Heat Index vs Feel like

2022-05-16 Thread Barry
Thanks for the comments, time to go and learn about Met and Python :-) Barry On Monday, May 16, 2022 at 11:40:11 a.m. UTC-4 peterq...@gmail.com wrote: > Calculations are here: > https://github.com/weewx/weewx/blob/6c90a174f9cf81b1b93b83b70a426199a51b47ba/bin/weewx/wxformulas.py > > see the

Re: [weewx-user] Windchill vs Heat Index vs Feel like

2022-05-16 Thread p q
Calculations are here: https://github.com/weewx/weewx/blob/6c90a174f9cf81b1b93b83b70a426199a51b47ba/bin/weewx/wxformulas.py see the comment: The 'new' algorithm uses: https://www.wpc.ncep.noaa.gov/html/heatindex_equation.shtml On Mon, May 16, 2022 at 8:18 AM Greg Troxel wrote: > > Barry

Re: [weewx-user] Windchill vs Heat Index vs Feel like

2022-05-16 Thread Greg Troxel
Barry writes: > Now that I have (with help from the group) Weefx and the tempest running > well I would lie to throw out a Met. > > Current observation > > Wind 210/3knts > Humidity75% > Temp 20.1C > Dewpoint15.5C > > Wind Chill 20.1C > Heat Index20.1C >

[weewx-user] Windchill vs Heat Index vs Feel like

2022-05-16 Thread Barry
Now that I have (with help from the group) Weefx and the tempest running well I would lie to throw out a Met. Current observation Wind 210/3knts Humidity75% Temp 20.1C Dewpoint15.5C Wind Chill 20.1C Heat Index20.1C Feels Like 21.5C >From what I have

[weewx-user] Windchill stored as heatindex

2019-10-13 Thread Hyrules Hyrules
I have been reading about heat index and looking at the NOAA formula to calculate the heatindex but it seems there is something wrong in the archive table as it stores the heatindex as the windchill value. Is this a bug ? I'm using a vantage pro 2 and MySQL to store data. Thanks. -- You

Re: [weewx-user] Windchill generated wrong when using WMR89 and not getting outdoor temp readings

2018-09-15 Thread Thomas Keffer
In general, when emitting a value, WeeWX defers to the hardware. After all, that's why you own it. Occasionally, the hardware is wrong, and that seems to be the case for you. One option is to set up [StdQC] to filter out the "bonker" values. Or, let the software calculate the values. Or,

[weewx-user] Windchill generated wrong when using WMR89 and not getting outdoor temp readings

2018-09-15 Thread T
Hi, I've noticed a thing when setting up my WMR89. I've found the "Windchill generated wrong." thread from december 2017 but I don't see any conclusive solution there, just a suggestion to switch to software windchill, and then a suggestion there might be a bug in the WMR200 driver. On my WMR89,

[weewx-user] Windchill

2018-08-10 Thread Kalli
Hallo bei mir ist der Windchill gleich wie die Aussentemperatur. normal muss der Windchill doch andere werte liefern. mfg. Kalli -- You received this message because you are subscribed to the Google Groups "weewx-user" group. To unsubscribe from this group and stop receiving emails from it,

[weewx-user] Windchill generated wrong.

2017-12-25 Thread gjr80
Also, what type of station? Gary -- You received this message because you are subscribed to the Google Groups "weewx-user" group. To unsubscribe from this group and stop receiving emails from it, send an email to weewx-user+unsubscr...@googlegroups.com. For more options, visit

[weewx-user] Windchill generated wrong.

2017-12-25 Thread gjr80
Not doubting your transcription but would be good to see the actual LOOP packet or REC record that gave the nonsense result. Gary -- You received this message because you are subscribed to the Google Groups "weewx-user" group. To unsubscribe from this group and stop receiving emails from it,

[weewx-user] Windchill generated wrong.

2017-12-25 Thread Mark Jenks
Yes, I live somewhere where the air hurts my face.. But that being said, when windchill hits -25, it calculates it wrong. Outside Temperature -9.4°F Wind Chill -24.6°F Heat Index -9.4°F Dewpoint -34.2°F Humidity 27% Barometer 30.507 inHg Barometer Trend (3 hours) 0.038 inHg Wind 8 mph from 288°