You have to "attach" a struct file, not just copy the text, because it
gets completely scrambled.
Anyway, it can't be correct. An anti ferromagnet must have "identical"
Cr atoms, only the spin is different.
But you have 3 different Cr atoms ?
Am 03.04.2011 10:13, schrieb pankaj srivastava:
> Res
In principle you have to test it and increase it eventually a couple of times.
However, I'm a bit surprised that the problem happens for L=4 ???
Am 03.04.2011 11:50, schrieb Lisa.Siggelkow at lrz.tu-muenchen.de:
> Dear Wien2k users,
>
> i am using Wien2k_10.1 and at the moment i am performing cal
When you do parallel calculations, the vector files are called
case.vector_1, ..2, ...
Thus also for the DOS you have to specify
x lapw2 -qtl -p
This will run only ONE lapw2-job, but use the parallel vectors.
Am 03.04.2011 10:42, schrieb Rajagopalan Mathrubutham:
> Dear Dr Blaha,
>
> Greeting f
attachment was scrubbed...
URL:
<http://zeus.theochem.tuwien.ac.at/pipermail/wien/attachments/20110403/126f4e2a/attachment.htm>
Dear Wien2k users,
i am using Wien2k_10.1 and at the moment i am performing calculations
concerning Bader's AIM. As i have the impression, that the charge density
calculated could be "better", i increased the default LM-list up to
LMMAX=8. I obtain an error message:
Error in LAPW1
'ATPAR' - more
--
An HTML attachment was scrubbed...
URL:
<http://zeus.theochem.tuwien.ac.at/pipermail/wien/attachments/20110403/0167ba3f/attachment.htm>
6 matches