Re: [Wien] STOP SPHBES - Error

2023-06-12 Thread Peter Blaha
Hi, This error is because of your settings for RKMAX together with the small H spheres. init_lapw in WIEN2k_23 would give by default RKMAX=3 leading to a matrixsize of about 6200. Your matrix size is more than 42000 !! ( 7 times as big as mine, would lead to a cputime 7^3 ~ 350 times

[Wien] STOP SPHBES - Error

2023-06-12 Thread Ilias Miroslav, doc. RNDr., PhD.
Dear Wien2k experts, the SCF lapw1 step gives me error "STOP SPHBES - Error" for my system - small Quartz slab with LvO2 on top of it. No symmetry, z lattice coordinate is the z-vacuum distance. Bottom Si atoms are H-passivated. The corresponding output file, LvO2onQg.output1 , shows this

[Wien] Stop Wien News Letter

2016-01-19 Thread rprasad
I wish receiving Wien News letter anymore. Thanks, R. Prasad ___ Wien mailing list Wien@zeus.theochem.tuwien.ac.at http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien SEARCH the MAILING-LIST at:

Re: [Wien] Stop Wien News Letter

2016-01-19 Thread Gavin Abo
I cannot unsubscribe you. However, I went to the mailman link below and submitted your email address using the unsubscribe box. You should receive an email containing a link that you have to click on to unsubscribe. Hopefully, the other 2,042 members on the mailing list roster do not do the

Re: [Wien] Stop!

2015-09-02 Thread Gavin Abo
Perhaps someone else understands your question; if not, you need to rephrase your question or provide more details on where it got stuck in the script. What I can tell you is that if you run init_lapw or initso_lapw and use Ctrl+Z before it completes, it is normal for the process to stop

[Wien] Stop and restart

2014-04-19 Thread leith...@gmail.com
Dear users: I am doing an optimization with -5 -2 0 2 5 volume change. Now I have finished -5 -2 calculation and the 0 calculation have run 5 cycles, but the electric power will be cut in a few hours so I have to stop it by .stop. My question is can we continue with the scf from where it

Re: [Wien] Stop and restart

2014-04-19 Thread Laurence Marks
If you know how to edit the optimize.job script, just use the -NI option for your run??? On Apr 19, 2014 1:16 PM, leith...@gmail.com leith...@gmail.com wrote: Dear users: I am doing an optimization with -5 -2 0 2 5 volume change. Now I have finished -5 -2 calculation and the 0 calculation

Re: [Wien] Stop and restart

2014-04-19 Thread eagle ying
Dear prof. Marks: Thanks for your hint. If one want to run scf after a previous scf cycle no matter finished or not, there is three options provided in w2web: save previous calculation and then start a new one; remove the files case.broyd and discard the results obtained before, -NI

Re: [Wien] stop calculation

2013-04-28 Thread Lyudmila Dobysheva
27.04.2013 14:17, Karima Karim wrote: :ENERGY convergence: 0 0.0001 .01566078 cycle 11 (Wed Apr 24 04:14:39 CET 2013) (70/89 to go) lapw0 (04:14:40) 34.1u 2.6s 31:18.12 1.9% 0+0k 842304+25464io 15350pf+0w lapw1 -up(04:46:15) 627.2u 27.9s 8:19:49.15

[Wien] stop calculation

2013-04-27 Thread Karima Karim
Dear All I used the wien2k-11 I got error message ( stop calculation ) when I run l'optimization the antifferromagnetic  please what and where is the probleme  start (Thu Apr 18 03:58:00 CET 2013) with lapw0 (80/99 to go) cycle 1 (Thu Apr 18 03:58:00 CET 2013) (80/99 to go)

[Wien] STOP CORE END

2012-03-19 Thread Stefaan Cottenier
My guess: there is no error at all here. Depending on the OS and compiler (and/or compiler settings?), the 'end' message can be different. Probably the piece of code in SRC_lcore was compiled in a different way (even with a different compiler?) then the rest of your wien2k installation. Maybe

[Wien] STOP: YOU MUST MOVE THE ORIGIN OF THE UNIT CELL (see K2UCl5_SC.outputs )

2011-05-20 Thread Ghosh SUDDHASATTWA
Dear Prof.Blaha and Wien2k users, The supercell for K2UCl5 is attached. During init_lapw and lstart The following error comes STOP: YOU MUST MOVE THE ORIGIN OF THE UNIT CELL (see K2UCl5_SC.outputs ) Can you please suggest what I have to do for soling this problem The idea is to have two

[Wien] STOP: YOU MUST MOVE THE ORIGIN OF THE UNIT CELL (see K2UCl5_SC.outputs )

2011-05-20 Thread Stefaan Cottenier
The mailing list should be your last resort to solve problems, not your first. In this case, you should do what the message suggests: STOP: YOU MUST MOVE THE ORIGIN OF THE UNIT CELL (see K2UCl5_SC.outputs ) Because that answers your question: Can you please suggest what I have to do for

[Wien] STOP: YOU MUST MOVE THE ORIGIN OF THE UNIT CELL (see K2UCl5_SC.outputs )

2011-05-20 Thread Ghosh SUDDHASATTWA
[mailto:wien-bounces at zeus.theochem.tuwien.ac.at] On Behalf Of Stefaan Cottenier Sent: Friday, May 20, 2011 12:29 PM To: A Mailing list for WIEN2k users Subject: Re: [Wien] STOP: YOU MUST MOVE THE ORIGIN OF THE UNIT CELL (see K2UCl5_SC.outputs ) The mailing list should be your last resort to solve

[Wien] stop error

2009-10-02 Thread sun
--- Original Message --- From:sun z.m.sun at aist.go.jp To: A Mailing list for WIEN2k users wien at zeus.theochem.tuwien.ac.at Date:Wed, 09 Sep 2009 15:28:10 +0900 Subject: [Wien] stop error Dear Wien2K users: I have a problem here

[Wien] stop error

2009-09-14 Thread sun
Thanks a lot for your advice. Actually I used exactly the same structure file and exactly the same input for the runs as used in the other system which worked. I also tried the new version of Wien2K which did not work either. However, I will try the new version again. Thanks again. ZM On Fri,

[Wien] stop error

2009-09-09 Thread sun
Dear Wien2K users: I have a problem here with the Wien2K_08 and I hope to get some help here. I used Wien2K for some calculation with no problems for some 2 years. Recently I have bought a new work station and installed Wien2k there. The installation has finished with no error and I can run the