Dear all
I'm working in magnetic alloy.I want to doping Co1-xFex with VCA
approximation,I changed struct,in2,inst.How do I change in inst file's Co for
x=0.5?
inst file for Co
Ar 3
3, 2,2.0 N
3, 2,2.0 N
3,-3,3.0 N
3,-3,0.0 N
4,-1,1.0 N
4,-1,1.0 N
inst file for Fe
Ar 3
3, 2,2.0 N
3,
a) You don't need to modify case.inst. Do a normal initialization
without VCA, and before the scf cycle change Z in struct and
eventually NE in in2 file.
b) FeCo is a particular BAD example for VCA (see the Magnetism lecture
by K.Schwarz on our workshop programs). VCA works only if you
2 matches