Re: [Wien] error in x lstart

2014-08-25 Thread Minghao Zhang
Thanks for the kind instruction. I already fixed the structure problem, and it seems fine right now after initialization. But when I tried to run the SCF, I encountered another problem with error file like this: Error in LAPW1 'INILPW' - can't open unit: 18 'INILPW' -filename:

[Wien] error in x lstart

2014-08-24 Thread Minghao Zhang
Hi all, *I encountered a problem while I run the initialization process for LiCoO2 structure through w2web.* *Here is my structure file:* LiCoO2 R LATTICE,NONEQUIV.ATOMS: 3166_R-3m MODE OF CALC=RELA unit=ang 5.310133 5.310133 26.550663 90.00 90.00120.00 ATOM -1:

Re: [Wien] error in x lstart

2014-08-24 Thread Laurence Marks
Your structure is wrong, the lattice constants are always in au. Hence your RMT's are anomalously small and everything has gone wrong;. On Sun, Aug 24, 2014 at 12:01 PM, Minghao Zhang miz...@eng.ucsd.edu wrote: Hi all, *I encountered a problem while I run the initialization process for

Re: [Wien] error in x lstart

2014-08-24 Thread Minghao Zhang
My structure unit is indeed au although it read in ang in the structure file. I think this is a common situation when we use the w2web interface to generate the struct.file. There has to be other problem. Check this link from wien2k site for the unit information:

Re: [Wien] error in x lstart

2014-08-24 Thread Laurence Marks
No, look at your RMT, they are a factor of two too small. On Aug 24, 2014 12:23 PM, Minghao Zhang miz...@eng.ucsd.edu wrote: My structure unit is indeed au although it read in ang in the structure file. I think this is a common situation when we use the w2web interface to generate the

Re: [Wien] error in x lstart

2014-08-24 Thread Gavin Abo
Looks to me that your atomic positions are in the hexagonal setting, when they need to be in the rhombohedral setting [http://www.mail-archive.com/wien%40zeus.theochem.tuwien.ac.at/msg05554.html] and your hexagonal lattice constants seem fine. On 8/24/2014 11:01 AM, Minghao Zhang wrote: Hi