Re: [Wien] GHOST BANDS error

2023-07-13 Thread Natalia Andreeva
Thank you very much! On Thu, Jul 13, 2023 at 12:17 PM wrote: > Hi, > > As mentioned by Peter Blaha, this is not possible to do a calculation > with a hybrid functional using XC_HYB_LDA_*, XC_HYB_GGA_* or > XC_HYB_MGGA_* from Libxc. Actually, without entering into detail, this > is not possible

Re: [Wien] GHOST BANDS error

2023-07-13 Thread fabien . tran
Hi, As mentioned by Peter Blaha, this is not possible to do a calculation with a hybrid functional using XC_HYB_LDA_*, XC_HYB_GGA_* or XC_HYB_MGGA_* from Libxc. Actually, without entering into detail, this is not possible to use Libxc at all for a hybrid calculation (the results would be

Re: [Wien] GHOST BANDS error

2023-07-08 Thread Natalia Andreeva
Thank you very much! With Best Regards, Natalia On Sat, Jul 8, 2023 at 2:39 PM Peter Blaha wrote: > As was mentioned before, you can't use the XC_HYB_GGA_XC_* switches. > > > In addition: The manual says for NBAND: use "at least" NE+1. Then it > should run through. > > But this does not

Re: [Wien] GHOST BANDS error

2023-07-08 Thread Peter Blaha
As was mentioned before, you can't use the XC_HYB_GGA_XC_* switches. In addition: The manual says for   NBAND:  use "at least" NE+1. Then it should run through. But this does not mean that such a calculation is good. You should use more bands for the second variation HF step, depending on

Re: [Wien] GHOST BANDS error

2023-07-08 Thread Natalia Andreeva
Dear Professor Blaha, I use wien21. I calculate the BaTiO3 structure, atom 1 is Ba, RMT(Ba) = 2.44; RMT(Ti) = 1.72; RMT(O) = 1.55. First I run the SCF calculation on WC, it converges successfully. Results of scf calculation for WC potential: Insulator, EF-inconsistency corrected :GAP (global) :

Re: [Wien] GHOST BANDS error

2023-07-07 Thread Peter Blaha
I need some more information: Are you using wien23 or an earlier version ? What is your system (struct file), in particular what is atom 1; its RMT, ... Such a large EF is rather unusual (except for 5f systems) and for sure the resulting E-parameters as you showed below must lead to