Hi,
the metal option works only with TEMP Fermi method in in2. Maybe you have
TETRA, in this case Fermi level is shifted by 0.5 Ry, leading to wrong
shielding.
regards
Robert
On 18 April 2014 AM 11:07:27 Jing-Han Chen wrote:
Dear WIEN2k users
We tried to use NMR package to verify GaP
Dear staff:
The purpose of my calculations is to get quantity coulomb potential of
a certain system and I've already get the result.
But I'm confused with the component of coulomb potential, is the
contribution of core electron also counted in or just the valence
electrons are calculated?
FYI, from slide 12 of
http://indico.cern.ch/event/30902/session/19/contribution/95/material/slides/1.pdf
:
The coulomb potential Vc is a central quantity in any theoretical
calculation (part of the Hamiltonian) and is obtained from all charges
rho (electronic + nuclear) in the system.
On
You should check for ghoststate:
http://www.mail-archive.com/wien%40zeus.theochem.tuwien.ac.at/msg08960.html
You can try adjusting RMT or energy parameters:
http://www.mail-archive.com/wien%40zeus.theochem.tuwien.ac.at/msg09842.html
http://www.wien2k.at/reg_user/faq/qtlb.html
If starting
It is the coulomb potential due to ALL charges in your system.
This means the TOTAL electron density + nuclear charges.
Am 21.04.2014 16:11, schrieb huimei liu:
Dear staff:
The purpose of my calculations is to get quantity coulomb potential
of a certain system and I've already get the