Thanks you sir,
The value of RMT automatically determined by SET RMT programs. We attached
here input file. if we not SET the RMT values its shows following error
ATOM 1 Fe1ATOM 4 Fe4
RMT( 1)=2.2 AND RMT( 4)=2.2
SUMS TO 4.4 LT. NN-DIST= 4.68872
ATOM 2 Fe2
Try viewing that struct file in XCrysDen, Venus or whatever...
What you have here is one long thin pillar with alternating
thin layers of Fe,Co,Al and a huge gap between z=0.4 and z=.85
If this is what you want, it does not surprise me that Wien is
having some trouble with it.
--
Dr. Martin
I'm not understand this is problem with structure or not? actually there
was a vacuum of 30 Ang and Thickness of Fe, Co, Al layers was ~31 Angstrom
fixed, thickness according to unit cell of Fe, Co and Al. and Fe, Co and Al
structure was prepared by w2web
The thin film structure was prepared by
I do not feel qualified to categorically state that it cannot be done
like that, but your struct file does look decidedly strange to me. How did you
arrive at the individual metal layers - at least the aluminum sublattice looks
a bit unusual, with some of the Al-Al distances about half the value
Dear wien2k users,
A new version of the NMR-module SRC_nmr.tar.gz is available for
download from the files download-area.
This directory should replace the old SRC_nmr directory. You can use the
update option of siteconfig or do it manually (including the
adaptation of the Makefile.