[Wien] how to increase precision of calculations?

2014-11-29 Thread tran
Actually, the most important is maybe the number of bands calculated by lapw1 which are used for the 2nd variational procedure for the spin-orbit coupling. So, to increase Emax in case.in1 (up to 20 Ry or even more) should be tried. F. Tran On Sat, 29 Nov 2014, t...@theochem.tuwien.ac.at wrote:

Re: [Wien] how to increase precision of calculations?

2014-11-29 Thread tran
Hi, For the convergence, I suggest to increase RKmax further. RKmax=8 is (very) good, but also not fully converged usually. Going up to RKmax=10 makes sense. It's difficult to say for the step at 0.003. Maybe the k-mesh is still not dense enough. An increase of GMAX (12 -> 18) in case.in2 is wort

[Wien] how to increase precision of calculations?

2014-11-29 Thread Martin Gmitra
Dear Wien2k users, We are calculating spin-orbit coupling splitting of valence band in wurtzite GaAs using mBJ. Since we are interested in a fine structure close to Gamma point, we need to achieve sufficient accuracy. I am attaching a plot of the valence band spin-orbit coupling splitting (divided

[Wien] What's the crystal structure of NaCl in antiferromagnetic calculation

2014-11-29 Thread Abed Reg
Dear Wien2k users To do the antiferromagnetic calculation for the bcc Cr, we use the P cubic structure with 2 atoms; and for the fcc Ni we use the P cubic structure with 4 atoms. If we want to do a antiferromagnetic calculation for NaCl cubic structure with 2 atoms, what will be the structure in

Re: [Wien] The number of atoms in antiferromagnetic calculation

2014-11-29 Thread Abed Reg
Thanks Mr Gavin for your contribution and for your help. Thank you again -- Mr: A.Reggad Laboratoire de Génie Physique Université Ibn Khaldoun - Tiaret Algerie ___ Wien mailing list Wien@zeus.theochem.tuwien.ac.at http://zeus.theochem.tuwien.ac.at/mai

Re: [Wien] The number of atoms in antiferromagnetic calculation

2014-11-29 Thread Gavin Abo
In StructGen, if you select space group R with a=5.572783 b=5.572783 c=27.300952 (in bohr) alpha=90 beta=90 gamma=120 Ni1 (0,0,0) Ni2 (0.5,0.5,0.5) O (0.25,0.25,0.25) O (0.75,0.75,0.75) you should get a "WARNING: Mult not equal. PLEASE CHECK outpunn-file" when you run "x nn" in w2web. Ho

Re: [Wien] The number of atoms in antiferromagnetic calculation

2014-11-29 Thread Abed Reg
Thank you Dr pieper and Mr gavin for your replies What i am doing is just a test of the antiferromagnetic calculation because i am a beginner. For that i want to know if the calculation lead to these results. I tested the two structures and i found the same results. Structure 1: 166 R-3m a=5.57

[Wien] PbTiO3.struct (strained)

2014-11-29 Thread Oleg Rubel
Dear Mostefa, the files you asked are enclosed. Please try and let me know whether it works for you. Note that the option -p... is not needed any longer. Thank you Oleg On Fri, Nov 28, 2014 at 6:12 PM, mostefa djermouni wrote: > Dear Oleg Rubel > > I need a structural fils (PbTiO3.struct) of

Re: [Wien] The number of atoms in antiferromagnetic calculation

2014-11-29 Thread pieper
What do you mean by 'true'? You did something - at least I am unable to guess what it exactly was that you did - and you got a result connected in a unique way with your doings. Up to that point your result is true. I never actually did the NiO example but with the moment EXACTLY 1.2 I suspect