Re: [Wien] Why the antiferromagnetic structure of Cr is still cubic
I want to say that the distortion does not completely solve the frustration in NiO The geometric frustration in magnetism is vast subject Cheers Pablo de la Mora De: Wienen nombre de Abderrahmane Reggad Enviado: jueves, 9 de junio de 2016 06:10:01 p. m. Para: wien@zeus.theochem.tuwien.ac.at Asunto: Re: [Wien] Why the antiferromagnetic structure of Cr is still cubic Thanks again Dr Delamora for your explanation Best regards -- Mr: A.Reggad Laboratoire de Génie Physique Université Ibn Khaldoun - Tiaret Algerie ___ Wien mailing list Wien@zeus.theochem.tuwien.ac.at http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien SEARCH the MAILING-LIST at: http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html
Re: [Wien] OS and processor instruction error
Dear Professor Peter, Thank you for the clarification, I did let it as default, I did not change it and still the same error occur. Le Jeudi 9 juin 2016 15h18, Peter Blahaa écrit : sgroup is a C-program. Thus it has nothing to do with the ifort-conmpiler options, but with your C-compiler. Did you use icc or just cc ?? It is probably best to leave it as set in the default. Am 06.06.2016 um 04:50 schrieb Gavin Abo: > The Intel compiler probably was not able to detect the processor(s) that > your system uses, such that it generated an executable using instruction > sets that are wrong for your system. The Haswell and Broadwell > processors use Advanced Vector Extensions 2 (AVX2) instructions [ > http://www.nas.nasa.gov/hecc/support/kb/recommended-compiler-options_99.html > ], but from your error message, it seems that you likely have a > processor like the Sandy Bridge or Ivy Bridge that does not support the > AVX2 instruction set. > > So, you will probably have to specify manually what the > processor-specific options should be for your system. Refer to the > Intel documentation for the version of the Intel compiler that you are > using to determine the processor-specific options. For example, if you > are using Intel Fortran Compiler 16.0, the User and Reference Guide for > it on the Intel website should be at: > > https://software.intel.com/en-us/node/579311 > > On 6/5/2016 2:14 PM, halim said wrote: >> Dear Wien2k users, >> >> When installing wien2k at cray system with the following bellow: >> >> I would like to ask you for linking my software using intelfortran >> and mkl: >> >> O Compiler options: -FR -mp1 -w -prec_div -pc80 -pad -ip >> -DINTEL_VML -traceback >> >> >> R R_LIB (LAPACK+BLAS): -lmkl_lapack95_lp64 -lmkl_intel_lp64 >> -lmkl_intel_thread -lmkl_core -openmp -lpthread >> >> >> >> But when I tried init_lapw : >> >> with x nn it is fine >> >> when typing >> x sgroup >> >> I got this error: Please verify that both the operating system and the >> processor support Intel(R) MOVBE, FMA, BMI, LZCNT and AVX2 instructions >> >> what is the origine of this error? >> >> >> >> Looking forward for your answer. >> >> Halim Said >> Univ Hail, SA > > > ___ > Wien mailing list > Wien@zeus.theochem.tuwien.ac.at > http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien > SEARCH the MAILING-LIST at: > http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html > -- -- Peter BLAHA, Inst.f. Materials Chemistry, TU Vienna, A-1060 Vienna Phone: +43-1-58801-165300 FAX: +43-1-58801-165982 Email: bl...@theochem.tuwien.ac.at WIEN2k: http://www.wien2k.at WWW: http://www.imc.tuwien.ac.at/staff/tc_group_e.php -- ___ Wien mailing list Wien@zeus.theochem.tuwien.ac.at http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien SEARCH the MAILING-LIST at: http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html ___ Wien mailing list Wien@zeus.theochem.tuwien.ac.at http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien SEARCH the MAILING-LIST at: http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html
Re: [Wien] Why the antiferromagnetic structure of Cr is still cubic
Thanks again Dr Delamora for your explanation Best regards -- Mr: A.Reggad Laboratoire de Génie Physique Université Ibn Khaldoun - Tiaret Algerie ___ Wien mailing list Wien@zeus.theochem.tuwien.ac.at http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien SEARCH the MAILING-LIST at: http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html
Re: [Wien] Why the antiferromagnetic structure of Cr is still cubic
No, because in NaCl you do not have magnetic moments that want to find order, so there is no frustration In NiO the distortion is a way out of this frustration De: Wienen nombre de Abderrahmane Reggad Enviado: jueves, 9 de junio de 2016 05:26:15 p. m. Para: wien@zeus.theochem.tuwien.ac.at Asunto: Re: [Wien] Why the antiferromagnetic structure of Cr is still cubic Thanks Dr Delamora for your reply Now I inderstand that and according to this raison "geometrical frustration" , is there any structural distortion in the planes (100) and (110) for the NaCl structure. Best regards -- Mr: A.Reggad Laboratoire de G?nie Physique Universit? Ibn Khaldoun - Tiaret Algerie ___ Wien mailing list Wien@zeus.theochem.tuwien.ac.at http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien SEARCH the MAILING-LIST at: http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html
Re: [Wien] Why the antiferromagnetic structure of Cr is still cubic
Thanks Dr Delamora for your reply Now I inderstand that and according to this raison "geometrical frustration" , is there any structural distortion in the planes (100) and (110) for the NaCl structure. Best regards -- Mr: A.Reggad Laboratoire de Génie Physique Université Ibn Khaldoun - Tiaret Algerie ___ Wien mailing list Wien@zeus.theochem.tuwien.ac.at http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien SEARCH the MAILING-LIST at: http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html
[Wien] electronic density
- I wonder about: On how to interpret the figures of electronic density. Where do I find references? Thank you - []'s Dr Antonio Vanderlei dos Santos [1] Links: -- [1] http://santoangelo.uri.br ___ Wien mailing list Wien@zeus.theochem.tuwien.ac.at http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien SEARCH the MAILING-LIST at: http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html
Re: [Wien] Why the antiferromagnetic structure of Cr is still cubic
In NiO the Ni makes an FCC structure, you cannot have an antiferromagnetic arrangement in a triangular lattice (for example in 1,1,1 planes), even less in the FCC, which is triangular in many planes, so there is what is called "geometrical frustration" On the other hand, in Cr you have the "Cr up" and "Cr dn" alternated and you can have a clear antiferromagnetic arrangement Pablo De: Wienen nombre de Abderrahmane Reggad Enviado: miércoles, 8 de junio de 2016 05:43 a. m. Para: wien@zeus.theochem.tuwien.ac.at Asunto: [Wien] Why the antiferromagnetic structure of Cr is still cubic Dear wien2k users I have read that the antiferromagnetic ordering is accompanied with a little structural distortion as in the case of NiO. This latter is characterized by a distortion from NaCl to rhomboherdral structure; but for the chromide Cr the structure is still cubic when there is a magnetic transition from paramagnetic to antiferromagnetic state. Best regards -- Mr: A.Reggad Laboratoire de Génie Physique Université Ibn Khaldoun - Tiaret Algerie ___ Wien mailing list Wien@zeus.theochem.tuwien.ac.at http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien SEARCH the MAILING-LIST at: http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html
[Wien] Use of -DParallel+ ?
Does anyone know why line 146 of SRC_lapwso/hsocalc.F has a "+" after the normal Parallel, i.e. #ifdef Parallel+ -- Professor Laurence Marks "Research is to see what everybody else has seen, and to think what nobody else has thought", Albert Szent-Gyorgi www.numis.northwestern.edu ; Corrosion in 4D: MURI4D.numis.northwestern.edu Partner of the CFW 100% program for gender equity, www.cfw.org/100-percent Co-Editor, Acta Cryst A ___ Wien mailing list Wien@zeus.theochem.tuwien.ac.at http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien SEARCH the MAILING-LIST at: http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html
[Wien] Running parallel job with Slurm+intel mpi
Dear Wien2k users, I am trying to do some calculation with a large system with mpi version but having problem with running the job. I have compiled Wien2k 14.2 with intel libraries and have generated all mpi executables. But our system requires us to use srun instead of mpirun. So I have changed parallel options to srun -n _NP_ -machinefile _HOSTS_ _EXEC_. I also have tried other options that I saw in the mailing list srun -n _NP_ but that didn't work. No new files are created and the dayfile is stuck in lapw0. case.dayfile: -- Calculating GaAs in /lunarc/nobackup/users/eishfh/WIEN2k/test/GaAs on au054 with PID 189944 using WIEN2k_14.2 (Release 15/10/2014) in /lunarc/nobackup/users/eishfh/SRC/Wien2k14.2-mpi start (Thu Jun 9 13:14:39 CEST 2016) with lapw0 (100/99 to go) cycle 1 (Thu Jun 9 13:14:39 CEST 2016) (100/99 to go) > lapw0 -p(13:14:39) starting parallel lapw0 at Thu Jun 9 13:14:39 CEST > 2016 .machine0 : 4 processors --- I understood from the userguide that the -p option in runsp_lapw picks up mpi version depending on the form of the .machines file. Here is the .machines file that I have used for this test calculation. # lapw0:au165 au165 au165 au165 1:au165 au165 au165 au165 granularity:1 extrafine:1 lapw2_vector_split:2 So I am wondering if anyone can tell me how can I fix the problem. Thanks, Fhokrul ___ Wien mailing list Wien@zeus.theochem.tuwien.ac.at http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien SEARCH the MAILING-LIST at: http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html
Re: [Wien] :WAR : LOPW-exhausted for atom ...
Dear Prof. Blaha, Thank you very much ! All the best, Luis 2016-06-09 10:07 GMT-03:00 Peter Blaha: > This is no problem. > > > Am 06.06.2016 um 16:16 schrieb Luis Ogando: > >> Dear Wien2k community, >> >>I am trying to optimize a cubic structure with MSR1a and I am getting >> the following message in practically all the SCF cycles. >> >> :WAR : LOPW-exhausted for atom 11 PASS 1 had to reduce check 0.01 >> >>After checking it in the mailing list and noticing that the PASS is >> always 1 and that "check" is always reduced to 0.01, I believe that it >> is not a serious problem. Anyway, I would like to be sure. Can anyone >> confirm this to me ? >>Please, do not hesitate in asking me more information. >>Thanks in advance, >> Luis >> >> >> >> ___ >> Wien mailing list >> Wien@zeus.theochem.tuwien.ac.at >> http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien >> SEARCH the MAILING-LIST at: >> http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html >> >> > -- > -- > Peter BLAHA, Inst.f. Materials Chemistry, TU Vienna, A-1060 Vienna > Phone: +43-1-58801-165300 FAX: +43-1-58801-165982 > Email: bl...@theochem.tuwien.ac.atWIEN2k: http://www.wien2k.at > WWW: http://www.imc.tuwien.ac.at/staff/tc_group_e.php > -- > ___ > Wien mailing list > Wien@zeus.theochem.tuwien.ac.at > http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien > SEARCH the MAILING-LIST at: > http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html > ___ Wien mailing list Wien@zeus.theochem.tuwien.ac.at http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien SEARCH the MAILING-LIST at: http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html
Re: [Wien] :WAR : LOPW-exhausted for atom ...
This is no problem. Am 06.06.2016 um 16:16 schrieb Luis Ogando: Dear Wien2k community, I am trying to optimize a cubic structure with MSR1a and I am getting the following message in practically all the SCF cycles. :WAR : LOPW-exhausted for atom 11 PASS 1 had to reduce check 0.01 After checking it in the mailing list and noticing that the PASS is always 1 and that "check" is always reduced to 0.01, I believe that it is not a serious problem. Anyway, I would like to be sure. Can anyone confirm this to me ? Please, do not hesitate in asking me more information. Thanks in advance, Luis ___ Wien mailing list Wien@zeus.theochem.tuwien.ac.at http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien SEARCH the MAILING-LIST at: http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html -- -- Peter BLAHA, Inst.f. Materials Chemistry, TU Vienna, A-1060 Vienna Phone: +43-1-58801-165300 FAX: +43-1-58801-165982 Email: bl...@theochem.tuwien.ac.atWIEN2k: http://www.wien2k.at WWW: http://www.imc.tuwien.ac.at/staff/tc_group_e.php -- ___ Wien mailing list Wien@zeus.theochem.tuwien.ac.at http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien SEARCH the MAILING-LIST at: http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html
[Wien] Regarding XAS calculations in WIEN2K
Dear All In XAS calculations, do we include the electric quadrupole transitions. Regards Azam ___ Wien mailing list Wien@zeus.theochem.tuwien.ac.at http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien SEARCH the MAILING-LIST at: http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html
[Wien] Why the antiferromagnetic structure of Cr is still cubic
Dear wien2k users I have read that the antiferromagnetic ordering is accompanied with a little structural distortion as in the case of NiO. This latter is characterized by a distortion from NaCl to rhomboherdral structure; but for the chromide Cr the structure is still cubic when there is a magnetic transition from paramagnetic to antiferromagnetic state. Best regards -- Mr: A.Reggad Laboratoire de Génie Physique Université Ibn Khaldoun - Tiaret Algerie ___ Wien mailing list Wien@zeus.theochem.tuwien.ac.at http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien SEARCH the MAILING-LIST at: http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html
[Wien] Why the antiferromagnetic structure of Cr is still cubic
Dear wien2k users I have read that the antiferromagnetic ordering is accompanied with a little structural distortion as in the case of NiO. This latter is characterized by a distortion from NaCl to rhomboherdral structure; but for the chromide Cr the structure is still cubic when there is a magnetic transition from paramagnetic to antiferromagnetic state. Best regards -- Mr: A.Reggad Laboratoire de Génie Physique Université Ibn Khaldoun - Tiaret Algerie ___ Wien mailing list Wien@zeus.theochem.tuwien.ac.at http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien SEARCH the MAILING-LIST at: http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html
Re: [Wien] OS and processor instruction error
sgroup is a C-program. Thus it has nothing to do with the ifort-conmpiler options, but with your C-compiler. Did you use icc or just cc ?? It is probably best to leave it as set in the default. Am 06.06.2016 um 04:50 schrieb Gavin Abo: The Intel compiler probably was not able to detect the processor(s) that your system uses, such that it generated an executable using instruction sets that are wrong for your system. The Haswell and Broadwell processors use Advanced Vector Extensions 2 (AVX2) instructions [ http://www.nas.nasa.gov/hecc/support/kb/recommended-compiler-options_99.html ], but from your error message, it seems that you likely have a processor like the Sandy Bridge or Ivy Bridge that does not support the AVX2 instruction set. So, you will probably have to specify manually what the processor-specific options should be for your system. Refer to the Intel documentation for the version of the Intel compiler that you are using to determine the processor-specific options. For example, if you are using Intel Fortran Compiler 16.0, the User and Reference Guide for it on the Intel website should be at: https://software.intel.com/en-us/node/579311 On 6/5/2016 2:14 PM, halim said wrote: Dear Wien2k users, When installing wien2k at cray system with the following bellow: I would like to ask you for linking my software using intelfortran and mkl: O Compiler options:-FR -mp1 -w -prec_div -pc80 -pad -ip -DINTEL_VML -traceback R R_LIB (LAPACK+BLAS): -lmkl_lapack95_lp64 -lmkl_intel_lp64 -lmkl_intel_thread -lmkl_core -openmp -lpthread But when I tried init_lapw : with x nn it is fine when typing x sgroup I got this error: Please verify that both the operating system and the processor support Intel(R) MOVBE, FMA, BMI, LZCNT and AVX2 instructions what is the origine of this error? Looking forward for your answer. Halim Said Univ Hail, SA ___ Wien mailing list Wien@zeus.theochem.tuwien.ac.at http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien SEARCH the MAILING-LIST at: http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html -- -- Peter BLAHA, Inst.f. Materials Chemistry, TU Vienna, A-1060 Vienna Phone: +43-1-58801-165300 FAX: +43-1-58801-165982 Email: bl...@theochem.tuwien.ac.atWIEN2k: http://www.wien2k.at WWW: http://www.imc.tuwien.ac.at/staff/tc_group_e.php -- ___ Wien mailing list Wien@zeus.theochem.tuwien.ac.at http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien SEARCH the MAILING-LIST at: http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html
[Wien] fatband in local coordinate axis
Is the following procedure correct for plotting fat band in local coordinate system? Fisrt edit case.inq Second: x lapw1 -band Third: x qtl -band finally x spaghetti ___ Wien mailing list Wien@zeus.theochem.tuwien.ac.at http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien SEARCH the MAILING-LIST at: http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html
[Wien] :WAR : LOPW-exhausted for atom ...
Dear Wien2k community, I am trying to optimize a cubic structure with MSR1a and I am getting the following message in practically all the SCF cycles. :WAR : LOPW-exhausted for atom 11 PASS 1 had to reduce check 0.01 After checking it in the mailing list and noticing that the PASS is always 1 and that "check" is always reduced to 0.01, I believe that it is not a serious problem. Anyway, I would like to be sure. Can anyone confirm this to me ? Please, do not hesitate in asking me more information. Thanks in advance, Luis ___ Wien mailing list Wien@zeus.theochem.tuwien.ac.at http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien SEARCH the MAILING-LIST at: http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html