Dear wien users
I have optimized an hexagonal structure with the package 2Doptimize and I
want to know in which file we find the optimal values of the volume V and
the ratio c/a.
Best regards
--
Mr: A.Reggad
Laboratoire de Génie Physique
Université Ibn Khaldoun - Tiaret
Adresse: BP 144 AL ATTAF
Thank you again Prof Blaha for your answer
Sorry for difference value. it's 0.0001 Ry.
Best regards
--
Mr: A.Reggad
Laboratoire de Génie Physique
Université Ibn Khaldoun - Tiaret
Adresse: BP 144 AL ATTAF AIN DEFLA
Tel: +213(0)561861963
Algerie
___
Wien
From the plot you sent earlier the difference in these 2 calculations
was 0.0001 Ry, not 0.001 !!??
Of course, with your default convergence criterium these 2 calculations
are the same.
On 01/04/2017 04:16 PM, Abderrahmane Reggad wrote:
Thank you Dr Pieper for you answer
According to th
Thank you Dr Pieper for you answer
According to the results with a difference of 0.001 Ry , can we considere
the 2 calculations are the same ?
Best regards
--
Mr: A.Reggad
Laboratoire de Génie Physique
Université Ibn Khaldoun - Tiaret
Adresse: BP 144 AL ATTAF AIN DEFLA
Tel: +213(0)561861963
Alg
On 01/03/2017 04:35 AM, Koyel Bandopadhyay wrote:
> When do we need to do shifteig?
> Is it done before/after w2w step?
Normally (when you have a correct Fermi energy), you do not need it at all.
If you need to use it, it is between w2w and wannier90, since it acts on
case.eig. If you want to ad
I would argue that you did NOT find a difference between two
calculations of the same thing. You only told the program to stop early.
If you want to distiguish between states with a difference in energy
smaller than the default 0.001 Ry, then you have to converge (with
regard to ALL numeric pa