Re: [Wien] paramagnetic or diamagnetic

2017-05-10 Thread Peter Blaha

Yes.
Of course the trace in case.xim is what you want.

The :NMRXIM is the contribution of Xi to the chemical shift at the nucleus.

On 05/10/2017 09:36 AM, karima Physique wrote:

Thank you very much for you answers
Is there a difference between trace of magnetic susceptibility in the
file case.xim and :NMRXIM in the file case.outputnmr_integ because they
have two different values?


___
Wien mailing list
Wien@zeus.theochem.tuwien.ac.at
http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
SEARCH the MAILING-LIST at:  
http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html



--

  P.Blaha
--
Peter BLAHA, Inst.f. Materials Chemistry, TU Vienna, A-1060 Vienna
Phone: +43-1-58801-165300 FAX: +43-1-58801-165982
Email: bl...@theochem.tuwien.ac.atWIEN2k: http://www.wien2k.at
WWW:   http://www.imc.tuwien.ac.at/TC_Blaha
--
___
Wien mailing list
Wien@zeus.theochem.tuwien.ac.at
http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
SEARCH the MAILING-LIST at:  
http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html


Re: [Wien] paramagnetic or diamagnetic

2017-05-10 Thread karima Physique
Thank you very much for you answers
Is there a difference between trace of magnetic susceptibility in the file
case.xim and :NMRXIM in the file case.outputnmr_integ because they have two
different values?
___
Wien mailing list
Wien@zeus.theochem.tuwien.ac.at
http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
SEARCH the MAILING-LIST at:  
http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html