Thank you so much Sir.
On Tue, May 23, 2017 at 3:02 AM, Laurence Marks
wrote:
> If you have a structure with high symmetry such that the atom
> positions are not variables, then you do not relax the positions.
>
> Do not change one unless you have a really good
If you have a structure with high symmetry such that the atom
positions are not variables, then you do not relax the positions.
Do not change one unless you have a really good physical reason, otherwise GIGO.
On Mon, May 22, 2017 at 4:06 PM, fatima DFT wrote:
> Dear Dr.
Dear Dr. Tran,
I just finished the calculation for structure relaxation using: min -j
'runsp_lapw -p -ec 0.0001 -cc 0.001 -i 800 -fc 2 -NI'
at the output it seems to me that my structure converses without any
problem but in job file I see an error:
and I am getting below message:
Image
A NxNxN mesh in WIEN2k is maybe not exactly the same as a NxNxN mesh in QE.
On Monday 2017-05-22 21:47, fatima DFT wrote:
Date: Mon, 22 May 2017 21:47:41
From: fatima DFT
Reply-To: A Mailing list for WIEN2k users
To: A Mailing list for
Thank you Sir,
I could not understand the reply completely.
Please make it little easy up to level of a DFT beginner.
What I supposed to do is:
use a 2x2x2 mesh in QE and go to higher mesh till I get desired
accuracy in ENE or DIS conversance.
Suppose I got the 8x8x8 mesh where my conversance
Yes if the QE and WIEN2k k-meshes are exactly the same.
They may differ because of an applied shift for instance.
This may be more difficult for metals because of the different
treatment close to the Fermi energy (smearing vs. Tetrahedron),
but maybe this is not that crucial.
On Monday
Dear Wien2k users,
Is it possible that we optimize the number of k-point using Quantum
espresso and then use optimized mesh in Wien2k?
Warm regards
Fatima
___
Wien mailing list
Wien@zeus.theochem.tuwien.ac.at
Dear Prof. Karel, Thank you very much for the reply
and help! I have done the same calculations as you suggested, but when I try
to plot them in xmgrace separately for spin-up and spin-down channel I fail to
get the two separate independent plots. Although the same can
Sure. That's what you normally do as long as you don't include SO
interaction.
...
x optic -c -up
x joint -up
x kram -up
And then you get case.epsilonup Repeat the same with switches -dn and get
case.epsilondn These two (permittivities) have to be added up to get
what you measure e.g.
The Traceback error message is from python. Its trying to do what
berrypi tells it to do, so module berrypi is found and probably
installed ok.
However, berrypi wants python to import numpy - and that is not found.
Most probably something went wrong when you installed numpy (or
Dear Wien2k users,
As announced previously, this year the traditional WIEN2k-workshop will
be held from
18. - 22. Sept. 2017 at the TU Vienna, Austria.
Registration is now open (see http://www.wien2k.at)
In order to allow many of you to participate, we have tried to make the
registration