Re: [Wien] Energy density units in r2v file

2016-02-12 Thread tran
One more thing: you should use the options VX_TAU and VX_TAU-TAUW only with PBE clmsum/vrespsum (i.e., post-PBE plotting). Otherwise the plots will be wrong. On Fri, 12 Feb 2016, t...@theochem.tuwien.ac.at wrote: Hi, Concerning units, it's a mess in WIEN2k. In the file $WIENROOT/SRC_lapw0/vxcl

Re: [Wien] Energy density units in r2v file

2016-02-12 Thread tran
Hi, Concerning units, it's a mess in WIEN2k. In the file $WIENROOT/SRC_lapw0/vxclm2.f (version 14) I can see that if the keyword VX_TAU is used then the units of tau^{KS} are Hartree/bohr^3. However, with VX_TAU-TAUW, the units of tau^{KS}-tau^{W} are Ryd/bohr^3. I guess that ATU and ANG should

[Wien] Energy density units in r2v file

2016-02-12 Thread Nikola Novakovic
Hello everybody, just to be sure, which units are used for TAU (and TAUW) in r2v file output from lapw0? According to UG, the units for energy density should be Ryd/bohr^3? Also, does ATU/ANG flag in in5 file in any way change units if r2v file with TAU(-TAUW) data is passed to lapw5 as input in r