I think I found it. Thanks, all.
I'll let you know the results.
http://forum.mikrotik.com/viewtopic.php?t=210&highlight=long+cable&sid=5d5d6558c2bc21460b84df74a2cba94b
Brian
Brian Rohrbacher wrote:
I'm already at 10mb half.
Where is this long cable setting?
Brian
JohnnyO wrote:
Ethernet port acting up ? As in connecting / disconnecting ? Make sure
you have it set for "long cable", if that doesn't work - disable
auto-negotiation and try 100mbps half duplex, if that don't work -
10mbps full duplex and then last try 10mbps HALF duplex......
JohnnyO
x
-----Original Message-----
From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On
Behalf Of Brian Rohrbacher
Sent: Tuesday, September 12, 2006 7:56 AM
To: WISPA General List
Subject: Re: [WISPA] MT power supplies
It's actually the ethernet port acting up. Thought maybe it was lack of
power.
Mac Dearman wrote:
I don't think a RB532 will run 2 SR5's with a 2' patch cable and a
48VDC power supply without s0me weirdness happening. I only put one
Super Range card in a RB532 and one Atheros or Prism card.
Mac
-----Original Message-----
From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On
Behalf Of Brian Rohrbacher
Sent: Monday, September 11, 2006 11:29 PM
To: Conversations over a new WISP Trade Organization
Subject: [WISPA] MT power supplies
I have a RB 532 on 300 foot of cat 5 with 2 sr5.
I'm using poe 48v .700a power supply.
I'm seeing weirdness.
Do I have enough "juice"
Brian
--
WISPA Wireless List: wireless@wispa.org
Subscribe/Unsubscribe:
http://lists.wispa.org/mailman/listinfo/wireless
Archives: http://lists.wispa.org/pipermail/wireless/