To All, Tues. 11/15, we had a sever thunder strom move thru SoMich, Wed. 11/16, was a mild day, I checked the NOC at 5:00 AM, after the storm and all was well, AP's and Bridges. All on line, I had an appointment, 75 miles away, got back at 3:00 PM. One of the AP's, sB APPO, on the tower had crashed, I cycled the power and its back on line.
Wed. 11/16 night, very windy to 50 MPH, snow and dropped to 22*F. This morning 4 sB ABT's have died. I have looked at 2, both are accessable via simpleMonitor, appear to be OK, however. I cannot ping thru them, no access to NOC, I can ping the radios easly. They show, both 80% RSSI, only 1.75 and .35 miles from tower. I replaced one with a Tranzeo TR-CPE80-15, now all is well with that user. Now I must go the the other 3, replace one w/ another TR-CPE80-15, maybe a third. If the 4th has the same problem then that will get a TR- 200-15, its 4 miles out. Question: What are you all using to replace sB devices, beside Tranzeo???, I have 7 Tranzeos left. They have worked well so far. Any suggestions?? Any thing is appreciated. What do you think Marlon??? Ron Wallace Hahnron, Inc. 220 S. Jackson St. Addison, MI 49220 Phone: (517) 547-8410 Mobile: (517) 605-4542 e-mail: [EMAIL PROTECTED] -- WISPA Wireless List: wireless@wispa.org Subscribe/Unsubscribe: http://lists.wispa.org/mailman/listinfo/wireless Archives: http://lists.wispa.org/pipermail/wireless/