-Original Message-
From: Dominique Louis [mailto:dominique.lo...@amxeurope.com]
Sent: 27 July 2011 11:45
To: General discussion for Windows Installer XML toolset.
Subject: [WiX-users] Launching Exe at end of Installation...
Hi all,
I have the following Custom Action, based
Hi all,
Is it possible to launch an exe at the end of the second or 3rd msi installer
has run via a bootstrap process?
Thanks,
DOMINIQUE LOUIS | SENIOR IS DEVELOPER
AMX EUROPE | 6TH FLOOR SALISBURY HOUSE | LONDON | EC2M 5QQ
MOBILE: +44 (0) 7799.82.46.85 | PHONE: +44 (0) 207.652.9472
Hi WiX gurus,
Once the files from my embedded MSM have been installed can I launch this
other install before the main install finishes? Or should rip the MSM out and
chain the 2 MSI's instead?
Thanks,
Dominique Louis
Hi all,
I have an existing *.wixproj and have been given a 3rd party *.msm which I
need to incorporate into my installer. I can't seem to find any documentation
on how to do this. Any insights?
Alternatively, how can I convert my *.wixproj into a *.vdproj as I know in
Visual Studion 2010, I
Modules.
Also add a MergeRef element under one of your Features (just like you would a
ComponentRef). For example:
MergeRef Id=merge_3rdparty/
Dan
-Original Message-
From: Dominique Louis [mailto:dominique.lo...@amxeurope.com]
Sent: Thursday, June 30, 2011 11:03 AM
To: General
to email the log to us at the press of a button or 2.
Any ideas
Thanks,
DOMINIQUE LOUIS | IS DEVELOPER, AMX DIGITAL MEDIA GROUP
dominique.lo...@amxeurope.com
AMX
AMX UK
Auster Road
Clifton Moor
York, North Yorkshire
United Kingdom
YO30 4GD
+44 (0) 1904 343100 office
+44 (0) 1904 343101
. Has anyone else come
across this?
DOMINIQUE LOUIS | IS DEVELOPER, AMX DIGITAL MEDIA GROUP
AMX
AMX UK
Auster Road
Clifton Moor
York, North Yorkshire
United Kingdom
YO30 4GD
+44 (0) 1904 343100 office
+44 (0) 1904 343101 fax
AMX South
6th Floor Salisbury House
London Wall
London
United
/en/msi/articles/VistaMSI/index.htm
Phil Wilson
-Original Message-
From: Dominique Louis [mailto:dominique.lo...@amxeurope.com]
Sent: Tuesday, November 24, 2009 9:11 AM
To: General discussion for Windows Installer XML toolset.
Subject: [WiX-users] Wix not working with UAC and Windows 7
Just wondering if there is any sort of update on the WiX Script
repository that a few people talked about a few months ago. How can we
submit scripts.
I've got some scripts which I've built up over the last few months,
which I think others could find useful.
DOMINIQUE LOUIS | IS DEVELOPER, AMX
value of IIS Management and Script Tools.
The ListView is only ever populated and shown after this value is set.
What am I missing or doing wrong?
DOMINIQUE LOUIS | IS DEVELOPER, AMX DIGITAL MEDIA GROUP
AMX UK| 6TH FLOOR SALISBURY HOUSE,| LONDON WALL | LONDON | EC2M 5QQ
AMX
AMX UK
Auster Road
works fine for IIS 56
Thanks.
DOMINIQUE LOUIS | IS DEVELOPER, AMX DIGITAL MEDIA GROUP
AMX UK| 6TH FLOOR SALISBURY HOUSE,| LONDON WALL | LONDON | EC2M 5QQ
AMX
AMX UK
Auster Road
Clifton Moor
York, North Yorkshire
United Kingdom
YO30 4GD
+44 (0) 1904 343100 office
+44 (0) 1904 343101 fax
XML toolset.
Subject: Re: [WiX-users] Error 0x80040154: failed to
getIID_IIMSAdminBaseobject with IIS 7
Hi,
Have you installed the II6 backward compatability in II7, the
wix IIS utilities need them?
Dave
-Original Message-
From: Dominique Louis [mailto:dominique.lo...@amxeurope.com
You are correct, IIS6 compatibility is required for it to install
correctly.
Does anyone have a script that correctly detects IIS6 compatibility mode
under IIS 7?
-Original Message-
From: Dominique Louis [mailto:dominique.lo...@amxeurope.com]
Sent: 11 November 2009 13:09
To: General
-
From: Dominique Louis [mailto:dominique.lo...@amxeurope.com]
Sent: 11 November 2009 14:40
To: General discussion for Windows Installer XML toolset.
Subject: Re: [WiX-users] Error 0x80040154:
failedtogetIID_IIMSAdminBaseobject with IIS 7
You are correct, IIS6 compatibility is required
,
DOMINIQUE LOUIS | IS DEVELOPER, AMX DIGITAL MEDIA GROUP
AMX UK| 6TH FLOOR SALISBURY HOUSE,| LONDON WALL | LONDON | EC2M 5QQ
AMX
AMX UK
Auster Road
Clifton Moor
York, North Yorkshire
United Kingdom
YO30 4GD
+44 (0) 1904 343100 office
+44 (0) 1904 343101 fax
AMX South
6th Floor Salisbury House
like it only supports 16x16x16 colours ( yuck ).
Dominique.
-Original Message-
From: Dominique Louis [mailto:dominique.lo...@amxeurope.com]
Sent: 02 November 2009 10:18
To: General discussion for Windows Installer XML toolset.
Subject: [WiX-users] ListView Icon inconsistency...
Hi all
your own custom table, then you would
return all the entries as well as define other information in the table
(description, how to install etc).
Phil Wilson
-Original Message-
From: Dominique Louis [mailto:dominique.lo...@amxeurope.com]
Sent: Thursday, October 29, 2009 10:31 AM
?
Thanks.
DOMINIQUE LOUIS | IS DEVELOPER, AMX DIGITAL MEDIA GROUP
AMX UK| 6TH FLOOR SALISBURY HOUSE,| LONDON WALL | LONDON | EC2M 5QQ
AMX
AMX UK
Auster Road
Clifton Moor
York, North Yorkshire
United Kingdom
YO30 4GD
+44 (0) 1904 343100 office
+44 (0) 1904 343101 fax
AMX South
6th Floor
Message-
From: Dominique Louis [mailto:dominique.lo...@amxeurope.com]
Sent: 29 October 2009 16:19
To: General discussion for Windows Installer XML toolset.
Subject: [WiX-users] Retrieving a list of all the Properties in the
PropertyTable...
Hi all,
Background :
I'm trying to build
PopulateProductInstanceComboBox gComboBoxView,
Session.Property(PRODUCTREGISTRYPATH)
End Function
So when GetProductInstances() is called, the gSessionDatabase object is
instantiated and ready to work.
Dominique.
-Original Message-
From: Dominique Louis [mailto:dominique.lo...@amxeurope.com]
Sent: 23 October
oView, sProductInstance, intI
intI = intI + 1
Next
' clean up
Set aProductInstances = Nothing
End Function
Any ideas?
Thanks.
DOMINIQUE LOUIS | IS DEVELOPER, AMX DIGITAL MEDIA GROUP
AMX UK| 6TH FLOOR SALISBURY HOUSE,| LONDON WALL
SharpDevelop has a design for WiX which I've used to tweak UI elements,
and I think VS 2010 will have one built in as well, when that's
released.
Dominique.
-Original Message-
From: Slide [mailto:slide.o@gmail.com]
Sent: 20 October 2009 04:32
To: General discussion for Windows
duringruntime
Dominique Louis wrote:
There must be at least 1 dummy ListItem, otherwise the appropriate
table
will not be created.
The http://wix.sourceforge.net/manual-wix2/wix_xsd_ensuretable.htm
EnsureTable element can be used to cleanly accomplish this:
e.g. EnsureTable Id
I'd love to come along :). Anything exciting happening... Who are the
Larockos?
Me thinks this was not meant for this list.
Dominique.
-Original Message-
From: Chris Lord [mailto:chris.l...@atterotech.com]
Sent: 19 October 2009 17:19
To: wix-users
Subject: Re: [WiX-users] How to
So I guess the invite doesn't stand then, I feel hurt :).
I hate it when emails get crossed in the ether.
-Original Message-
From: Chris Lord [mailto:chris.l...@atterotech.com]
Sent: 19 October 2009 17:26
To: wix-users
Subject: Re: [WiX-users] How to populate a list box in a msi
Id=MsiLogging Value=voicewarmup!
Wendell
On Mon, Oct 12, 2009 at 9:08 AM, Dominique Louis
dominique.lo...@amxeurope.com wrote:
Hi Blair,
How does one set the MsiLogging property in WiX? Is this via a custom
action or PropertyRef of some kind?
Dominique,
-Original Message-
From
There are several ways to do it apparent, but this is what works for
me...
Set up your control up like this...
Control Id=CmbSQLServerInstance Property=SQLSERVERINSTANCE
Type=ComboBox Height=15 Width=140 X=14 Y=93 Text=Ppphhh
ComboList=yes ToolTip=The instance of SQL Server you would like to
I also thought I needed the same thing for a pre-requisites screen, but
then I thought of another solution.
Use a ListView. The ListItem for ListView has a Bitmap attribute, so you
could use that to display ticks, crosses or penguins.
Then again, I don't know how much interactivity you wanted,
Hi Blair,
How does one set the MsiLogging property in WiX? Is this via a custom
action or PropertyRef of some kind?
Dominique,
-Original Message-
From: Blair [mailto:os...@live.com]
Sent: 10 October 2009 21:36
To: 'General discussion for Windows Installer XML toolset.'
Subject: Re:
No fix/work around for this issue then?
Dominique.
-Original Message-
From: Dominique Louis [mailto:dominique.lo...@amxeurope.com]
Sent: Thu 10/8/2009 9:31 PM
To: wix-users@lists.sourceforge.net
Subject: [WiX-users] Please wait while the installer finishes determiningyour
disk space
Why no use ServiceInstall etc to install the service, but then change the
appropriate user info via the WiX registry calls?
That way MSI is in charge of correctly uninstalling and removing the
appropriate registry settings.
Dominique.
-Original Message-
From: Dave Kolb
From: Dominique Louis [dominique.lo...@amxeurope.com]
Sent: Thursday, 8 October 2009 4:10 AM
To: General discussion for Windows Installer XML toolset.
Subject: Re: [WiX-users] Creating SQLServer Users/Logins
Thanks for sharing this with us. I think it may just
Hi all
I have 6 MSIs chained together via Setupbld. On some machines, notably XP, I
get a pop-up box with
Please wait while the installer finishes determining your disk space
requirements and no matter how long we leave it, it never finishes the check.
If I shut down the installer and try
=True
]]
/CustomAction
But it seems that the SetConnectionStringVB code is never called from
the combobox's DoAction.
What have I done wrong?
Thanks,
DOMINIQUE LOUIS | IS DEVELOPER, AMX DIGITAL MEDIA GROUP
AMX
AMX UK
Auster Road
Clifton Moor
York, North Yorkshire
United Kingdom
this to do the attach process, passing the file
The alternate method to attaching databases is to script out you
database creation into SLQ Scripts and use the WIX SqlScript custom
actions to create the database.
Michael
-Original Message-
From: Dominique Louis [mailto:dominique.lo
the attachment of aforementioned user to the
DB?
4. Are there better/easier ways of doing what I'm trying to do?
I hope that all makes sense.
DOMINIQUE LOUIS | IS DEVELOPER, AMX DIGITAL MEDIA GROUP
AMX UK| 6TH FLOOR SALISBURY HOUSE,| LONDON WALL | LONDON | EC2M 5QQ
www.amx.com
AMX
AMX UK
Auster Road
)
OR NOT WIX_DIRECTX_VERTEXSHADERVERSION)
Or possibly (more simply, if the values don't really matter):
(NOT WIX_DIRECTX_PIXELSHADERVERSION) AND (NOT
WIX_DIRECTX_VERTEXSHADERVERSION)
-Original Message-
From: Dominique Louis [mailto:dominique.lo...@amxeurope.com]
Sent: Friday, October 02, 2009 8:03 AM
To: General
question is, Is it possible to get some Script=vbscript code to
correctly return a exit code or 1 or 3?
I suppose it is the equivalent of a main() returning a value.
I'm guessing it must be simple in Vbscript, but I can't find anything
about it anywhere.
Thanks
DOMINIQUE LOUIS | IS DEVELOPER, AMX
This would be perfect for http://wixrepo.codeplex.com/
Also: Looks good, looking forward to playing around with it, although
the company I work for, will have to support 2008 as well in the near
future.
/Thomas
-Original Message-
From: Dominique Louis [mailto:dominique.lo...@amxeurope.com
the
WIX_DIRECTX_PIXELSHADERVERSION and WIX_DIRECTX_VERTEXSHADERVERSION
variables set with the right values.
What am I missing/doing wrong?
Thanks,
DOMINIQUE LOUIS | IS DEVELOPER, AMX DIGITAL MEDIA GROUP
AMX UK| 6TH FLOOR SALISBURY HOUSE,| LONDON WALL | LONDON | EC2M 5QQ
www.amx.com
AMX
AMX UK
Hi all,
Is there a way to only allow Administrators to install your msi?
Thanks,
DOMINIQUE LOUIS | IS DEVELOPER, AMX DIGITAL MEDIA GROUP
AMX UK| 6TH FLOOR SALISBURY HOUSE,| LONDON WALL | LONDON | EC2M 5QQ
www.amx.com
AMX
AMX UK
Auster Road
Clifton Moor
York, North Yorkshire
United Kingdom
If you move the WebSite declaration inside a Component it should delete it on
uninstall.
Be aware though that if your WebSite somehow maps to Default Web Site then it
will delete that as well.
Dominique.
-Original Message-
From: Scharp, Craig [mailto:craig.sch...@zytax.com]
Sent:
I think this would be a great idea, and would certainly save everyone
time in the long run, if it was done well.
A repository for CustomActions with full source would also be useful,
maybe broken up into language categories ( VbScript, Jscript, C/C++,
.NET, Delphi etc )
Dominique.
-Original
? The internet
was not helpful either.
Thanks,
DOMINIQUE LOUIS | IS DEVELOPER, AMX DIGITAL MEDIA GROUP
AMX UK| 6TH FLOOR SALISBURY HOUSE,| LONDON WALL | LONDON | EC2M 5QQ
www.amx.com
AMX
AMX UK
Auster Road
Clifton Moor
York, North Yorkshire
United Kingdom
YO30 4GD
+44 (0) 1904 343100 office
+44
Never mind, found it at
HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\ServiceProvider\Serv
iceType\W3SVC\TcpPort
Used the wrong search criteria in Google.
Dominique.
-Original Message-
From: Dominique Louis [mailto:dominique.lo...@amxeurope.com]
Sent: 18 September 2009 15:42
.
DOMINIQUE LOUIS | IS DEVELOPER, AMX DIGITAL MEDIA GROUP
AMX UK| 6TH FLOOR SALISBURY HOUSE,| LONDON WALL | LONDON | EC2M 5QQ
www.amx.com
AMX
AMX UK
Auster Road
Clifton Moor
York, North Yorkshire
United Kingdom
YO30 4GD
+44 (0) 1904 343100 office
+44 (0) 1904 343101 fax
AMX South
6th Floor
[mailto:b...@joyofsetup.com]
Sent: 17 September 2009 12:51
To: General discussion for Windows Installer XML toolset.
Subject: Re: [WiX-users] 4 Msi's in one exe via setupbld.exe...
Dominique Louis wrote:
1. How can I replace the Icon in Setup.exe at build-time?
Not directly exposed.
2
-Original Message-
From: Dominique Louis [mailto:dominique.lo...@amxeurope.com]
Sent: 15 September 2009 14:53
To: General discussion for Windows Installer XML toolset.
Subject: Re: [WiX-users] Conditional installed based on REG_MULTI_SZ
value
I'm using v4.5.6001.22159 if that is any help
Science Park,
Glasgow G20 0SP
Email Disclaimer
-Original Message-
From: Dominique Louis [mailto:dominique.lo...@amxeurope.com]
Sent: 15 September 2009 09:42
To: General discussion for Windows Installer XML toolset.
Subject: Re: [WiX-users] Conditional installed based on REG_MULTI_SZ
and, esp. on Vista, incorrect installations/repairs cause
Windows
Installer to reject the scripting engine runtime). For reliability, a
C/C++
CA statically linked to its runtime is considered best practice.
-Original Message-
From: Dominique Louis [mailto:dominique.lo...@amxeurope.com]
Sent
Hi WiX gurus,
I'm using the supposed standard way of detecting multiple SQLServer
instances...
Property Id=SQLSERVER
RegistrySearch Id=SQLServer Root=HKLM
Key=SOFTWARE\Microsoft\Microsoft SQL Server Type=raw
Name=InstalledInstances/
/Property
Condition Message=This application requires
Disclaimer
-Original Message-
From: Dominique Louis [mailto:dominique.lo...@amxeurope.com]
Sent: 14 September 2009 11:29
To: wix-users@lists.sourceforge.net
Subject: [WiX-users] Conditional installed based on REG_MULTI_SZ value
Hi WiX gurus,
I'm using the supposed standard way of detecting
-
From: Dominique Louis [mailto:dominique.lo...@amxeurope.com]
Sent: 14 September 2009 12:48
To: General discussion for Windows Installer XML toolset.
Subject: Re: [WiX-users] Conditional installed based on REG_MULTI_SZ
value
MSSQLSERVER Is not a property, it is a literal string that should exist
Hi Jaspreet,
I have found that the COM registration output heat.exe produces did
not work for My COM dlls ( originally written in Delphi ).
Instead I had to go through a laborious process of downloading WiX 2 and
running tallow over my dll as follows...
Tallow.exe /s MyCOMstuff.dll
OK based on Pally's earlier post, it would seem that
SQLSERVERMSSQLSERVER or the property equivalent should work, but
neither works for me.
Do they work for anyone else?
-Original Message-
From: Dominique Louis [mailto:dominique.lo...@amxeurope.com]
Sent: 14 September 2009 15:54
No.
SC151456
Registered Office - Helix Building, West Of Scotland Science Park,
Glasgow G20 0SP
Email Disclaimer
-Original Message-
From: Dominique Louis [mailto:dominique.lo...@amxeurope.com]
Sent: 14 September 2009 14:26
To: General discussion for Windows Installer XML toolset.
Subject: Re
Environmental Solutions Limited. Registered in Scotland No.
SC151456
Registered Office - Helix Building, West Of Scotland Science Park,
Glasgow G20 0SP
Email Disclaimer
-Original Message-
From: Dominique Louis [mailto:dominique.lo...@amxeurope.com]
Sent: 14 September 2009 15:54
To: General
Limited. Registered in Scotland No.
SC151456
Registered Office - Helix Building, West Of Scotland Science Park,
Glasgow G20 0SP
Email Disclaimer
-Original Message-
From: Dominique Louis [mailto:dominique.lo...@amxeurope.com]
Sent: 14 September 2009 14:23
To: General discussion for Windows
59 matches
Mail list logo