Question #632092 on Yade changed:
https://answers.launchpad.net/yade/+question/632092
Bruno Chareyre proposed the following answer:
>the safe option is a "user choice" and implement several possible
scenarios.
Yes, best and only choice I guess. That is why I often reply to questions by
asking
Question #632092 on Yade changed:
https://answers.launchpad.net/yade/+question/632092
Bruno Chareyre proposed the following answer:
>I don't understand it when you say that some volume will be created
overall,
Setting equilibrium distance back to zero means that at equilibrium the
particles
Question #632015 on Yade changed:
https://answers.launchpad.net/yade/+question/632015
behzad posted a new comment:
Good, that's what I meant!
--
You received this question notification because your team yade-users is
an answer contact for Yade.
___
New question #632699 on Yade:
https://answers.launchpad.net/yade/+question/632699
Hi,
CohFrictMat was used to model breakage of brittle materials, but I have no idea
on how to select two parameters: alphaKr and alphaKtw.
In my previous simulations, I chose the default value (2.0) of alphaKr
Question #632670 on Yade changed:
https://answers.launchpad.net/yade/+question/632670
Status: Answered => Solved
xjin confirmed that the question is solved:
Thanks Jan Stránský, that solved my question.
--
You received this question notification because your team yade-users is
an answer
Question #632670 on Yade changed:
https://answers.launchpad.net/yade/+question/632670
Status: Open => Answered
Jan Stránský proposed the following answer:
> If the sample is cube, does it use coord_100?
what does "it" mean?
If the sample is cubic, the choice of coord should not matter (as
Question #630508 on Yade changed:
https://answers.launchpad.net/yade/+question/630508
Status: Open => Expired
Launchpad Janitor expired the question:
This question was expired because it remained in the 'Open' state
without activity for the last 15 days.
--
You received this question
Question #632670 on Yade changed:
https://answers.launchpad.net/yade/+question/632670
Status: Solved => Open
xjin is still having a problem:
Thanks for Jan Stránský!
For I am new to yade, I am confused about another problem .
If the sample is cube, does it use coord_100?
As in the
Question #632670 on Yade changed:
https://answers.launchpad.net/yade/+question/632670
Status: Answered => Solved
xjin confirmed that the question is solved:
Thanks Jan Stránský, that solved my question.
--
You received this question notification because your team yade-users is
an answer
Question #632670 on Yade changed:
https://answers.launchpad.net/yade/+question/632670
Status: Open => Answered
Jan Stránský proposed the following answer:
Hello,
coord_25 = mm+.25*(mx-mm)
# mx - mm = length of the sample along given axis
# mm + .25*(mx-mm) = mm+.25*length
# coord_25 ...
New question #632670 on Yade:
https://answers.launchpad.net/yade/+question/632670
I learn the example:
https://github.com/yade/trunk/blob/master/examples/concrete/triax.py
There is a parameter in the script approxSectionArea,which is shown like
this:
11 matches