Re: [Yade-users] [Question #315620]: The parameter calibration of CpmMat

2016-08-07 Thread liukeqi
Question #315620 on Yade changed: https://answers.launchpad.net/yade/+question/315620 Status: Answered => Solved liukeqi confirmed that the question is solved: Thanks Jan Stránský. It solved my problem. Sorry for the late reply. I just come back from the 7th International Conference on

Re: [Yade-users] [Question #315620]: The parameter calibration of CpmMat

2016-08-04 Thread Jan Stránský
Question #315620 on Yade changed: https://answers.launchpad.net/yade/+question/315620 Status: Open => Answered Jan Stránský proposed the following answer: Hello, But I do not know the reasonable range of the per microscope parameter. Can > you give me suggestions? For a set of reasonable

[Yade-users] [Question #315620]: The parameter calibration of CpmMat

2016-08-02 Thread liukeqi
New question #315620 on Yade: https://answers.launchpad.net/yade/+question/315620 Hello, I want to calibrate microscope parameters to simulate the stress-strain curve of concrete obtained by experiment in the reference[1]. But I do not know the reasonable range of the per