Mike,


To get it to link, I needed to create a symbolic link at
/usr/lib/libzonecfg.so -> libzonecfg.so.1.  Time to go searching for
linker options that I haven't needed before...  I haven't looked into
it, but for some reason I seem to get some useless events.  Consider
the following reboot:

# ./notify
foo 6 shutting_down running
foo 6 shutting_down shutting_down
foo 6 shutting_down shutting_down
foo 6 shutting_down shutting_down
foo 6 uninitialized shutting_down
foo 7 ready uninitialized
foo 7 ready ready
foo 7 running ready

I'm not sure why the newstate and oldstate would be the same.


This is a known problem. See bug 6377283. http://bugs.opensolaris.org/bugdatabase/view_bug.do?bug_id=6377283

Thanks,
Nick



In order for an approach using a program like the one above to be
useful there would need to be some way to indicate what the desired
state for the zone is in addition to the the state that it has just
transitioned to.

Mike


_______________________________________________
zones-discuss mailing list
zones-discuss@opensolaris.org

Reply via email to