edwar
seems like you have errros in you s-file of parameter file. not likely you
have a station called E 100. you shoudl try using the test data with the
default parameter file, it works. them modify for your need.
jens
On Wed, 20 Mar 2013, Edwar Alberto Zambrano Martinez wrote:
I am trying to automatically pick the phases but I got this in the
autopic.out:
Reading waveforms from file :
Parameter settings in file :\SEISMO\\DAT\AUTOPIC.INP
Station :E 100
Number of channels to process if there: 3
Quality ratio : 56.187096
D H M SEC DUR FRQ SNR STA NT NH NV NC Q PS AZI DA VEL DV
2 0 0 0.00 End of coda
Station :E 101
Number of channels to process if there: 3
Quality ratio : 52.306068
D H M SEC DUR FRQ SNR STA NT NH NV NC Q PS AZI DA VEL DV
2 0 0 0.00 End of coda
And the Seisan Console emits:
Inline image 1
Could you help me about this, please.
I aprreciate your cooperation and assistance.
--
Edwar Alberto Zambrano Martinez
Ingeniero Civil -UFPS
Magíster en Ciencias de la Tierra con énfasis en Geofísica -EAFIT
_______________________________________________
seisan mailing list
[email protected]
http://mailman.uib.no/listinfo/seisan