it all depends on the other trigger parameters. you might have two real
detections 9s apart. in any case i do not suppose you are triggering on
one station only. even if you get few too many triggers in one channel,
the network trigger will only use the common triggers.
jens
On Wed, 13 Nov 2013, Beatriz Gaite wrote:
Dear all,
I am detecting events with CONDET CAR in a 1-day-long mseed continuos data
in a Seiscomp strutured database. It works, but I detect the same event
twice. I have defined the trigger interval to 90 s (MIN TRIG INTERVAL
90.) in condet.par file, but I get triggers separated 9 s that correspond to
the same event. If I define (MIN TRIG INTERVAL 15.) I obtain the same
triggers.
Example of triggers that correspond to the same event:
20130910034215.630
20130910034224.550
Have anyone found it before? How can I solve it?
Many thanks in advance.
--