And Type 4 lines should be followed by a blank line. Thanks Jens!
*Branden Christensen* The Seismo Guys Blog: http://www.osop.com.pa/blog/the-seismo-guys/ Take a Virtual Tour: http://www.osop.com.pa/tour Sign up for the OSOP mailing list: http://www.osop.com.pa/about/osop-mailing-list/ OSOP, S.A. On Mon, Mar 17, 2014 at 10:06 PM, Jens Havskov <[email protected]>wrote: > brandon > > first header line must be type 1, remsaining header lines can come in any > order except spec lines that must come in pairs. if not they will not be > read. type 7 line should come before the readings but can be any place > among header lines. > > jens > > > On Mon, 17 Mar 2014, Branden Christensen wrote: > > Hi all: >> >> Buenas tardes. >> >> I have been digging through Appendix 1 - The Nordic format of the Seisan >> manual lately. >> In what order do the lines have to come in the S-file? This is not clearly >> stated in the manual and in the examples I notice that line "I" can come >> before or after line "6". Is there are preferred order? >> >> >> Kind Regards from Panama, >> >> Branden Christensen >> The Seismo Guys Blog: http://www.osop.com.pa/blog/the-seismo-guys/ >> Take a Virtual Tour: http://www.osop.com.pa/tour >> Sign up for the OSOP mailing >> list: http://www.osop.com.pa/about/osop-mailing-list/ >> >> OSOP >> >>
_______________________________________________ seisan mailing list [email protected] http://mailman.uib.no/listinfo/seisan