Sir
i am calculating the Richter magnitude from single station data. For that i 
using Z component (always????) of the trace after pressing WA and by selecting 
the window (4 -5 sec near S-wave arrival) i am getting the amplitude in nm. But 
in some cases the P wave component of Z is more than that of S-wave, at the 
same time the other  component E and N shows S wave amplitude more than P-wave. 
In such case which component i may use for magnitude calculation. 
Secondly E , N gives large ( large amplitude due to soil amplification ???) and 
Z traces gives less amplitude.
In such case which trace   one should use to calculate the Richter magnitude 
for local event (<100km) with what  filter range. 
Regards
Sachin