carlos
invrad has not been used much and it requires neqar data of good quality. we recommned to use amplitude ratios instead and focmec.

for your questions

all P'smust be read as Pg and with polarity, same with S so IP woul dnot work, see manual.

amplitude readings are made peak to peak, ideally for thsi to work, the first swing should be the biggest.

jens

On Mon, 20 Aug 2018, Carlos Roberto Pinto Oróstica wrote:

Dear all,

I'm kindly seeking help with moment tensor inversion program (INVRAD). I'm 
struggling to use this program (INVRAD) when im using it i get the message 
which says " 0 data for inversion, not enough". I'm not sure of what might be 
the problem, i have picked 10 clear P- phases (IP) and their amplitudes (AMPG) 
and 10 clear  S- phases.  
My other cuestion is how of to peak on the amplitud of S and P wave, How pick 
that? the
P-phase from the beginin to the first pick (1/4 ?)and the s-wave, is peak to 
peak (1/2 ?)o cero to
peak (1/4 ?). Thank.

--
Carlos Pinto Oróstica
Ingeniero en Construcción
F: 955180830
Temuco-Chile.

La información contenida en este correo electrónico y cualquier anexo o 
respuesta relacionada,
puede contener datos e información confidencial y no puede ser usada o 
difundida por personas
distintas a su(s) destinatario(s). Si usted no es el destinatario de esta 
comunicación, le
informamos que cualquier divulgación, distribución o copia de esta información 
constituye un
delito conforme a la ley chilena. Si lo ha recibido por error, por favor borre 
el mensaje y
todos sus anexos y notifique al remitente.
_______________________________________________
seisan mailing list
[email protected]
https://mailman.uib.no/listinfo/seisan
  • [seisan] INVRAD Carlos Roberto Pinto Oróstica
    • Re: [seisan] INVRAD Jens Havskov

Reply via email to