http://servicemix.org/site/servicemix-eip.html
1. "The Pipeline component is a bridge between an In-Only (or Robust-In-Only) MEP and an In-Out MEP." 2. "The StaticRecipientList component will forward an input In-Only or Robust-In-Only exchange to a list of known recipients." Try removing the pipeline. (If you need tracing/logging in the first step use WireTap) -- View this message in context: http://www.nabble.com/servicemix-eip-error%3A-Use-an-InOnly-or-RobustInOnly-MEP-tf1916514.html#a5248738 Sent from the ServiceMix - User forum at Nabble.com.