Hi Vitor, The default sensor is the internal voltage of the MSP430, referenced in the Msp430Adc12.h header file as "SUPPLY_VOLTAGE_HALF_CHANNEL". Specifically ADC channel 11 ((AVcc - AVss)/2). See chapter 17 of the user guide for the MSP430F1611 for details: http://www.ti.com/lit/ug/slau049f/slau049f.pdf,
Mike On Wed, Apr 25, 2012 at 2:16 AM, Vitor Pinheiro <[email protected]>wrote: > Hi! > > What is the default sensor of shimmer2r platform when using the Sense app? > What does it read on shimmer2r? > > Thanks, > -- > V.GilVitorino > > _______________________________________________ > Shimmer-users mailing list > [email protected] > https://lists.eecs.harvard.edu/mailman/listinfo/shimmer-users > >
_______________________________________________ Shimmer-users mailing list [email protected] https://lists.eecs.harvard.edu/mailman/listinfo/shimmer-users