Hi Vitor,

The default sensor is the internal voltage of the MSP430, referenced in the
Msp430Adc12.h header file as "SUPPLY_VOLTAGE_HALF_CHANNEL". Specifically
ADC channel 11 ((AVcc - AVss)/2). See chapter 17 of the user guide for the
MSP430F1611 for details: http://www.ti.com/lit/ug/slau049f/slau049f.pdf,

Mike