Dear All,

I want to build LabView .vi file to acquire data from 3 Shimmer units.
Collected data has to be saved in text file and, in the same time, display
in chart indicators.
I use following Shimmer configuration: *two Shimmer Wireless Sensor Units +
one **Shimmer Wireless Sensor Unit with **GYRO BOARD,
firmware: BoilerPlate_shimmer2r_14_06_2011.ihex*
*
*
In "LabView Instrument Driver-Library" I found LV example "Four Shimmer
Write". It seemed to be suitable for my needs after few corrects: add new
tab to display real-time data.

*First step.*
I started with one* *Shimmer Wireless Sensor Unit configured as
accelerometer. For Shimmer 1 (in "Four Shimmer Write.vi") modified file
"Four Shimmer Write.vi" looks like this:

[image: Obraz w treści 2]


According to "Shimmer 9DoF Calibration Application – User Manual, page
52" I selected columns 1 to 3 to display acceleration in three axes. It
works fine.

Then, I wanted to add chart to display GYROSCOPE data in the same manner. I
have a problem. I cannot find "INTEGRATED VI' for gyroscope. Moreover, I
cannot apply "9DOF INTEGRATED VI" for my configuration: *Shimmer Wireless
Sensor Unit with **GYRO BOARD.*
*
*
My first question is as follows: how can I acquire data from gyroscope (in
following configuration:Shimmer Wireless Sensor Unit with GYRO BOARD) using
"LabView Instrument Driver-Library" for Shimmer platform?


Best Regards,
Krzysztof Brzostowski

<<attachment: img1.png>>

_______________________________________________
Shimmer-users mailing list
[email protected]
https://lists.eecs.harvard.edu/mailman/listinfo/shimmer-users

Reply via email to