Dear All, I want to build LabView .vi file to acquire data from 3 Shimmer units. Collected data has to be saved in text file and, in the same time, display in chart indicators. I use following Shimmer configuration: *two Shimmer Wireless Sensor Units + one **Shimmer Wireless Sensor Unit with **GYRO BOARD, firmware: BoilerPlate_shimmer2r_14_06_2011.ihex* * * In "LabView Instrument Driver-Library" I found LV example "Four Shimmer Write". It seemed to be suitable for my needs after few corrects: add new tab to display real-time data.
*First step.* I started with one* *Shimmer Wireless Sensor Unit configured as accelerometer. For Shimmer 1 (in "Four Shimmer Write.vi") modified file "Four Shimmer Write.vi" looks like this: [image: Obraz w treści 2] According to "Shimmer 9DoF Calibration Application – User Manual, page 52" I selected columns 1 to 3 to display acceleration in three axes. It works fine. Then, I wanted to add chart to display GYROSCOPE data in the same manner. I have a problem. I cannot find "INTEGRATED VI' for gyroscope. Moreover, I cannot apply "9DOF INTEGRATED VI" for my configuration: *Shimmer Wireless Sensor Unit with **GYRO BOARD.* * * My first question is as follows: how can I acquire data from gyroscope (in following configuration:Shimmer Wireless Sensor Unit with GYRO BOARD) using "LabView Instrument Driver-Library" for Shimmer platform? Best Regards, Krzysztof Brzostowski
<<attachment: img1.png>>