Hi all, I have doubts on how to fill correctly the filter data. I have been reading some papers and articles and I want to apply some of the filters I saw for example:
“were filtered with a 2-pole Butterworth filter with a high-pass corner frequency at 1 Hz (12 db/oct) to allow for the full spectral content" However I don't know where I should put the values and what values. Should I put on the fpass1 = 0 and fstop1 = 1? Other examples: “The choice of selecting the high-pass filter corner frequency is application and muscle dependant. For applications involving isometric contractions or natural and common movements, such as non-spastic gait measurements, the recommended corner frequency is 20 Hz..." Where should I put this value on the Multi shimmer Sync app? Thanks for your help! Best, David Costa