Den 16.06.14 17:56, skrev Gabriele Spina:
Hi
I'm currently using Shimmer2r.
I have two questions about the Paramlogging application:
1) Is it possible to store calibrated data? I followed the calibration
procedure described in the manual and saved the calibration parameter in
my laptop.
By looking through the source code, it does not seem like there is this
option. You could implement this yourself. Look at how it is done in
BtStream.
2) Is it possible to define the range for the acceleration?
Yes, but you have to recompile. You can change
Accel.setSensitivity(RANGE_1_5G);
on line 329 in ParamLoggingP.nc to
Accel.setSensitivity(RANGE_6_0G);
I haven't done this myself so I can't guarantee this will work.
- Torstein Winterseth