Hi Derek,

We currently use VASP to relax our molecules down to 0.01 eV/Ang. However, we do this for the experimental structure before engaging in both volume and uniaxial compressions. For the compressions experiments, we generally like to relax to 0.03 eV/Ang; however, at some point ionic convergence just doesn't want to happen down to 0.03. In such cases we do everything we can to get convergence down to 0.05 - this we tend to deem publishable. Of course, we are currently trying to match our Siesta results to our VASP results with no success. If you end up successful in your endeavor, I would be very interested to know what parameters you had to adjust. Good Luck with your research!

Aaron


From: "Derek A. Stewart" <[EMAIL PROTECTED]>
Reply-To: "Siesta, Self-Consistent DFT LCAO program, http://www.uam.es/siesta"; <[EMAIL PROTECTED]>
To: [email protected]
Subject: [SIESTA-L] Defining an acceptable force tolerance for Siesta
Date: Mon, 6 Aug 2007 11:07:58 -0400

Hi everyone,

I wanted to get the Siesta community's perspective on what is an
acceptable tolerance for the maximum force during a structural relaxation
tolerance.  I know the default for the program is 0.04 eV/Ang, but I have
seen several papers that use lower force tolerances.  Would this imply
that some papers using the default 0.04 eV/Ang tolerance are not converged
enough?  Are there specific systems where more care is required?

Thanks,

Derek

################################