I'd like to add that if you really need a cell this big, you could save
memory in Order-N calculations by using the OrderN.LowerMemory flag. There's
also a flag called SaveMemory for parallel calculations (yours should
be, since a cell this big is not something for serial SIESTA). Finally, the
memory requirements should depend heavily on the basis set and the cutoff of
the LWF's.

You might also want to show us your .alloc output file and the section of
input .fdf containing your system specifications (the number of atoms, basis
set, etc.).


2007/3/19, Marcel Mohr <[EMAIL PROTECTED]>:

Dear Saswata,

and it looks like you use a huge unit cell. Is that really what you want?
(Remember, the lattice vectors are multiplied by the lattice constant)

Cheers Marcel

On Mon, 19 Mar 2007, Eduardo Anglada wrote:

> Dear Saswata,
>
> I think you don't have enough free memory.
>
> Regards,
>
> Eduardo
>

Reply via email to