Hi Julie,

 The same happened to us for a metallic system. The cure seems the
 use of a quite dense k-point grid (like 3K - 4K for the single
 atom primitive cell) and to keep the M&K grid fixed across the different
 deformations.

 Comments from the list appreciated.

 Regards,

 Roberto



On Fri, 20 Feb 2009, Julie Smart wrote:

Hello all,

I have a question about the changes of the total energy of a system under 
strain.

I have relaxed the system I have first under "Variablecell False" by "MaxForceTol 0.04eV/Ang" and 
then I turned on the "Variablecell true" and decreased the "MaxForceTol " to 0.01 eV/Ang to have 
the lattice parameters optimized as well.

When I change the lattice parameter in "z direction" to put the strain on the 
system sometimes the enrgy goes lower than the energy of the relaxed system!!! it may 
also happen when I insert the starin in further steps. I mean it first increases and then 
I see the decrease of the energy!!!

This is occuring to me while I have tried the optimization of my system checking 
different "energyshifts" and setting this parameter to the one that makes the 
energy of my system go to the lowst! The basis and the pseudo also have been checked very 
carefully.

Please let me know where I am going wrong.

Regards,
Julie




Reply via email to