Hi 

I was wondering if subtracting the energies from 2 different SIESTA runs is the 
right thing to do, I think in that case we imply that the energy reference in 
both cases was the same which I am not sure about.

I would appreciate any comments/clarifications.

Best Regards
Ahmed Huzayyin
PhD Candidate
ECE Department
University of Toronto




________________________________
From: Gregorio García Moreno <[email protected]>
To: [email protected]
Sent: Fri, April 16, 2010 10:21:52 AM
Subject: Re: [SIESTA-L] 

Hi, I work whith conjugated polymer. In this case, Ionization potential
or electron affinity are calculated for isolated molecule.
Thus, I push the molecule in a big supercell (supercell aproximation).
Then, I optimize the neutral and ionic states. Difference energy
between neutral and charge stated is hte ionization potencial or
electronic affinity.

El 16/04/2010 14:59, akshu hans escribió: 
Hi siesta users
>Can anyone please tell me how to calculate electron
>affinity and ionisation potential for a molecule (fullerene) using
>siesta. 
>


      

Responder a