Dear BR/Yujia,

The values of IP and EA, and of the work function as a consequence, is
sensitive to the confinement imposed on basis orbitals. Using the default
value of energy shift (0.01 Ry)
I also obtained a value of fermi level for Au(111), -4.1eV, which greatly
differs from those previously reported. I have obtained a better result,
-5.1eV, decreasing the value of energy shift to 0.001 Ry. As it is possible
to see in Nanotechnology *21* (2010) 065705, the value of Au(111) fermi
level converges to that obtained using plane waves (-5.25eV) in the limite
of very small basis set confinement.

Best,

Ronaldo

On Fri, Dec 24, 2010 at 5:33 AM, zjuyangyj <[email protected]> wrote:

>  Dear all,
> Recently I am calculating the work functions or fermi levels of different
> metals. However, my results seem to be incorrect. For example, I got the
> fermi level for Au as -3.68eV, which greatly differs from previous
> theoretically or experimentally reported values, which range from -4.8eV to
> -5.3eV. Also I got the fermi level for Pt as -3.99eV, also largely differing
> from correct values.
>
> I want to know what might be the possible reasons for incorrect fermi
> levels, and  when calculating fermi levels, what are  the
> important/relevant parameters? I am calculating very thin metal films (tens
> of atom layers), and I found the number of layers an important parameter.
> Also I want to know whether the fermi levels of bulk and thin film metal
> differs a lot.
>
> Thank you for your attention.
>
> BR/Yujia
>

Responder a